SciELO - Scientific Electronic Library Online

 
vol.75 issue1Myocardial perfusion with Tc-99Msestamibi and dipyridamole, and spect images during complete block of the left branch of the bundle of hisEstimation of the systolic parietal stress of the left ventricle by magnetic resonance imaging. A new approach to the study of the overload author indexsubject indexsearch form
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Archivos de cardiología de México

On-line version ISSN 1665-1731Print version ISSN 1405-9940

Abstract

DE LA PENA-ALMAGUER, Erasmo et al. Evaluation of left ventricular function with a 16-slice multidetector tomograph (MDCT-16): Correlation with cardiovascular magnetic resonance imaging. Arch. Cardiol. Méx. [online]. 2005, vol.75, n.1, pp.55-60. ISSN 1665-1731.

The evaluation of Left ventricular function has both prognostic as well as therapeutic implications in patients with heart disease. Non-invasive coronary angiography with computed tomography using 16 slices (MDCT-16) allows to obtain images of the coronary anatomy due to its high spatial and temporal resolution, and also, to obtain data regarding Left ventricular function. The objective of this study was to correlate the use of MDCT-16 forthe evaluation of the Left ventricular parameters using MRI as the Standard of reference Methods: MRI: Se A 1.5 Tesla GE Cvl Scanner optimized for cardiovascular applications was used. Using an ECG gated steady state fast precession sequence (SSFP, Thickness 10 mm, Flip Angle 45, FOV 36 cm. NEX 1, Frequency 256, Phase 128, Partial FOV 0.75, 16 VPS), 6 to 8 short axis images of from base to apex of the left ventricle were obtained. Tomography: Using a 16 slice Multidetector tomograph (GE Lightspeed) and using ECG synchronization, images of the heart were obtained after the administration of 80 mis. of no-ionic contrast. The images were reconstructed off-line to obtain from 6 to 8 slices in a similar fashion to that of MR. Both studies were independently analyzed by 2 operators who obtained the ventricular function data. Linear correlation and a Paired T Student test was used to analyze the data and was considered significant when p < 0.05. Results: 20 consecutive patients were evaluated with MDCT-16 and MRI, 18 males, mean age 52 ± 15 years. There was no significant difference among the measurements for cardiac CT and MRI of the end-diastolic volume (EDV) and end-sistolic volume (ESV), stroke volume (SV), LV Mass or LV ejection fraction (LVEF). Conclusion: This results show a high correlation among the clinically relevant ventricular function parameters evaluated by cardiovascular CT and MRI. This findings suggest that ventricular function can be successfully evaluated along with the coronary anatomy using MDCT-16.

Keywords : Ventricular function; Multislice CT; Cardiovascular MRI.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License