SciELO - Scientific Electronic Library Online

 
vol.12 issue2Effect of various pretreatments on anaerobic biodegradability and quality microbiology of waste activated sludgeCoffee grain rotary drying optimization author indexsubject indexsearch form
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Revista mexicana de ingeniería química

Print version ISSN 1665-2738

Abstract

FLORES, O. et al. Estimation of the condensation heat transfer coefficient for steam water at low pressure in a coiled double tube condenser integrated to a heat transformer. Rev. Mex. Ing. Quím [online]. 2013, vol.12, n.2, pp.303-313. ISSN 1665-2738.

An experimental study was conducted to calculate the condensation heat transfer coefficient of steam water in a double helical tube condenser. The steam flows through the inner tube and the cooling water flows in counter flow in the annular section. The operating pressure of the condenser is ranging from 4 kPa to 9 kPa and the Reynolds number of steam is ranging from 7200 to 23200. The mass flux of the cooling water is ranging from 450 kg/m2s to 850 kg/m2s. The heat transfer coefficient is calculated by two methods: the first is based on energy balance and heat transfer equations, and the second by Wilson Plot method. The heat transfer coefficient results shows similarity between both methods and it is ranging from 2200 W/m2oC to 55500 Wrm2oC. Furthermore, we propose a correlation for the condensation heat transfer coefficient based on the Nusselt, Reynolds and Prandtl numbers.

Keywords : heat transfer coefficient; steam; coiled condenser; Wilson Plot; heat transformer.

        · abstract in Spanish     · text in Spanish

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License