SciELO - Scientific Electronic Library Online

 
vol.15 issue3Digital counter cell design using carbon nanotube FETsDesign and evaluation of energy-efficient carbon nanotube FET-based quaternary minimum and maximum circuits author indexsubject indexsearch form
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Journal of applied research and technology

On-line version ISSN 2448-6736Print version ISSN 1665-6423

J. appl. res. technol vol.15 n.3 Ciudad de México Jun. 2017

https://doi.org/10.1016/j.jart.2016.12.007 

Articles

Comparison of power quality indices and apparent power (kVA) ratings in different autotransformer-based 30-pulse AC-DC converters

Rohollah Abdollahia  * 

aElectrical Engineering Department, Technical and Vocational University (Qom Boys Technical College), Qom, Iran


Abstract

Three-phase multipulse AC-DC converters (MPC) are developed for improving power quality to reduce harmonics in ac mains and ripples in dc output. This study, based on technical and economic factors, compares different autotransformer-based 30-pulse AC-DC converters. In this paper, the comparison of two topologies of autotransformer-based 30-pulse AC-DC converter has been presented. In topology A, three-phase AC voltages are given to the autotransformer, which produces five sets of three-phase voltage and, in topology B, three-phase AC voltages are given to the autotransformer, which produces three sets of five-phase voltages of same magnitude and distributed in time through phase shifts of 12o. Topology A included polygon, hexagon, star, fork, and T-connected autotransformer-based 30-pulse AC-DC converters, and topology B Included polygon, and T-connected autotransformer-based 30-pulse AC-DC converters. These converters have been implemented and simulation using Matlab/Simulink software for similar ratings under different load conditions has been performed. A set of power-quality indices on input ac mains and on a dc bus for a DTCIMD fed from different 30-pulse AC-DC converters is given to compare their performance. Economic comparison of 30 pulse AC-DC converters is based on the apparent power (kVA) ratings of the different autotransformer for 30 pulse AC-DC converters.

Keywords: AC-DC converter; Power quality; 30-pulse rectifier; Direct torque controlled induction motor drive (DTCIMD)

1. Introduction

Recent advances in solid state conversion technology have ledto the proliferation of variable frequency induction motor drives (VFIMD’s) that are used in several applications such as air conditioning, blowers, fans, pumps for waste water treatment plants, textile mills, rolling mills, etc. (Bose, 1998). The most practical technique in VFIMD’s is direct torque controlled strategy in that it offers better performance rather than the other control techniques. Direct Torque controlled technique is implemented involtage source inverter which is mostly fed from six-pulse diode bridge rectifier, Insulated gate bipolar transistors (IGBT’s) are employed as the VSI switches. The most important draw back of the six-pulse diode-bridge rectifier is its poor power factor injection of current harmonics into ac mains. The circulation of current harmonics into the source impedance yields in harmonic polluted voltages at the point of common coupling (PCC) and consequently resulting in undesired supply voltage conditions for costumers in the vicinity. The value of current harmonic components which are injected into the grid by nonlinear loads such as DTCIMD’s should be confined with in the standard limitations. The most prominent standards in this field are IEEE standard 519 (IEEE Standard 519-2014 (2014) and the International Electro technical Commission (IEC) 61000-3-2 IECStandard 61000-3-2: 2004 (2004).

Arc furnaces generate more harmonic current distortionand Static Power Converters (SPC’s) are the harmonic current source with the widest distribution in electrical systems. For DTCIMD’s one effective solution is to employ multipulse AC-DC converters. These converters are based on either phase multiplication or phase shifting or pulse doubling or a combination (Abdollahi, 2012h; Abdollahi & Jalilian, 2011, 2012b; Paice, 1996; Singh, Bhuvaneswari, & Garg, 2007b). Although, in the conditions of light load or small source impedance, line current total harmonic distortion (THD) will be more than 5%for up to 18-pulse AC-DC converters (Singh, Bhuvaneswari, & Garg, 2007c; Singh, Garg, & Bhuvaneswari, 2007). A hexagon-connected autotransformer-based 20-pulse AC-DC converter is reported in (Abdollahi, 2012a) which has THD variation of5.18-7.20% from full-load to light-load (20% of full-load). Azigzag-connected autotransformer-based 24-pulse AC-DC converter is reported in (Abdollahi, 2015a) which has THD variation of 3.95-5.85% from full-load to light-load (20% of full-load). Another T-connected autotransformer-based 24-pulse AC-DC converter has also been presented in Singh, Bhuvaneswari, and Garg (2006a), however, the THD of the supply current with this topology is reported to vary from 2.46% to 5.20% which is more than 5% when operating at light load.

The 36-pulse one was designed for vector controlled induction motor drives in Singh and Gairola (2007) which hasTHD variation of 2.03-3.74% from full-load to light-load (20% of full-load) respectively but the dc link voltage is higher than that of a 6-pulse diode bridge rectifier, thus making the scheme non applicable for retrofit applications. The delta/polygon-connected transformer-based 36-pulse AC-DC converter for power quality improvement in (Abdollahi, 2012d) which has THD variation of 2.92-3.89% from full-load tolight-load (20% of full-load) respectively and delta/fork, and delta/hexagon-connected transformer-based 36-pulse AC-DC converters have been reported (Abdollahi, 2012e, 2015b) forreducing the total harmonic distortion (THD) of the ac mains current. But these topologies require higher rating magnetics, resulting in the enhancement of capital cost. However, these topologies increase the rating of magnetic parts, which finally affects the total cost of the project. The magnetic rating ofthe multipulse AC-DC converter based on transformer topology is more than 100% of the load rating. In contrast, the autotransformer-based configurations (Paice, 1996) reduce the ratings of magnetic parts. This is true because of the fact that in this topology, only a portion of KVA rating of the induction motor should be beard by the magnetic coupling parts. Therefore, autotransformer-based configurations could significantly reduce the size and proportionally the weight of the transformer. Abdollahi (2012f, 2015c, 2012g) proposed tapped delta, polygon, T-connected autotransformer-based 36-pulse AC-DC converters, which supply induction motor drives to improvpower quality at the PCC. Although increasing the pulse number can bring dramatic improvement in different power quality indices, it will also make the autotransformer configuration become cumber some and more diode bridge rectifiers will berequired, leading to increased components and cost in the overall AC-DC converter system.

In this paper, the comparison of two topologies of autotransformer-based 30-pulse AC-DC converter has been presented. Topology A included polygon (Singh, Garg, &Bhuvaneswari, 2006), hexagon (Singh, Bhuvaneswari, & Garg, 2007a), star (Singh, Bhuvaneswari, Garg, & Chandra, 2006), fork (Abdollahi & Jalilian, 2012a), and T (Singh,Bhuvaneswari, & Garg, 2006b)-connected autotransformer-based 30-pulse AC-DC converters and topology B Included polygon (Abdollahi, 2012b), and T (Abdollahi, 2012c)-connected autotransformer-based 30-pulse AC-DC converters. This study, based on technical and economic factors, compares different autotransformer-based 30 pulse AC-DC converters. Simulation results of six-pulse and different 30-pulse AC-DC converters feeding a DTCIMD load are scheduled and various quality criteria such as THD of ac mains current, power factor, displacement factor, distortion factor, and THD of the supply voltage at PCC are compared. Economic comparison of different 30 pulse AC-DC converters is based on the apparent power (kVA) ratings of the 30 pulse AC-DC converters.

2. 30-Pulse AC-DC converter

In this paper, the comparison of two topologies of autotransformer-based 30-pulse AC-DC converter has been presented. In topology A, three-phase AC voltages are given to the autotransformer, which produces five sets of three-phase voltages, as shown in Fig. 1, and in topology B, three-phase AC voltages are given to the autotransformer, which produces three sets of five-phase voltages of same magnitude and distributed in time through phase shifts of 12o, as shown in Fig. 2. Topology A included polygon, hexagon, star, fork, and T-connected autotransformer-based 30-pulse AC-DC converters and topology B included polygon, and T-connected autotransformer-based 30-pulse AC-DC converters.

Fig. 1 Autotransformer based 30 pulse AC-DC converters (topology A). 

Fig. 2 Autotransformer based 30 pulse AC-DC converters (topology B). 

In order to implement a 30-pulse AC-DC converter (topol-ogy A) through paralleling five bridge rectifiers, i.e. five 6-pulse rectifiers, five sets of three-phase voltages with a phase difference of 120o between the voltages of each group and 12 o between the same voltages of the five groups are required. Accordingly, each bridge rectifier consists of 3 common-anodeand 3 common-cathode diodes (five 3-leg rectifiers). Autotransformer connections and its phasor diagram which shows the angular displacement of voltages are illustrated in Fig. 1. Theafore mentioned five voltage sets are called as (Va1, Vb1, Vc1) and (Va2, Vb2, Vc2) and (Va, Vb, Vc) and (Va3, Vb3, Vc3) and (Va4, Vb4, Vc4) that are fed to rectifiers I, II, III, IV and V, respectively. The same voltages of the five groups, i.e. Vai, are phase displaced of 12o. Va1 and Va3 has a phase shift of +12o and −12o from the input voltage of phase A, respectively. According to phasor diagram, the 3-phase voltages are made from ac main phase and line voltages with fractions of the primary winding turns which are expressed with the following relationships.

In order to implement a 30-pulse AC-DC converter (topology B) through paralleling three bridge rectifiers, i.e. three 10-pulse rectifiers, three sets of 5-phase voltages with a phase difference of 72o between the voltages of each group and 12 o between the same voltages of the three groups are required. Accord-ingly, each bridge rectifier consists of 5 common-anode and5 common-cathode diodes (three 5-leg rectifiers). Autotransformer connections and its phasor diagram which shows theangular displacement of voltages are illustrated in Fig. 2. Theaforementioned three voltage sets are called as (Va1, Va2, Va3, Va4, Va5) and (Vb1, Vb2, Vb3, Vb4, Vb5) and (Vc1, Vc2, Vc3, Vc4, Vc5) that are fed to rectifiers I, II and III, respectively. The samevoltages of the three groups, i.e. Vai, Vbi, and Vci, are phase displaced of 12 o. Vb1 and Vc1 has a phase shift of +12 o and −12 o from the input voltage of phase A, respectively. According to phasor diagram, the 5-phase voltages are made from ac mainphase and line voltages with fractions of the primary winding turns which are expressed with the following relationships.

3. Matlab-based simulation

The designed configurations were simulated using Matlab/Simulink software and power system block set (PSB) toolbox. In this model, a three-phase 460 V and 60 Hz network isutilized as the supply for the 30-pulse converters. The designed autotransformer is modeled via three multiwinding transformers. Multiwinding transformer block is also used to model IPT. At the converter output, a series inductance (L) and a parallel capacitor (C) as the dc link are connected to an IGBT-based voltage source inverter (VSI). VSI drives a squirrel cage induction motor employing direct torque controlled strategy. The simulated motor is 50 hp (37.3 kW), 4-pole, and Y-connected.Detailed data of the motor are listed in Appendix A. Simulation results are depicted in Figs. 3-5. Power quality parameters are also listed in Table 1 for 6-pulse, and different 30-pulse AC-DC converters. The rating of input transformer is calculated based on the simulated rms values of the voltage and current.

Table 1 Comparison of power quality parameters of different topologies. 

Sr. no. Topology % THD of V ac AC Mains current ISA (A) % THD of ISA, at Distortion factor, DF Displacement factor, DPF Power factor, PF
Light load Full load Light load Full load Light load Full load Light load Full load Light load Full load
1 6-Pulse 5.64 10.33 52.69 52.53 28.53 0.8850 0.9599 0.9858 0.9881 0.8730 0.9485
2 30-Pulse (A) Polygon 1.67 10.67 52.67 2 3.26 1.88 0.9994 0.9997 0.9925 0.9933 0.9920 0.9930
3 Hexagon 1.58 10.65 52.51 3.89 2.03 0.9992 0.9997 0.9942 0.9932 0.9935 0.9929
4 Star 1.40 10.55 52.55 4.00 1.49 0.9992 0.9998 0.9939 0.9924 0.9932 0.9922
5 Fork 1.08 10.56 53.56 1.95 1.13 0.999 0.999 0.988 0.981 0.988 0.981
6 T 1.52 10.47 52.51 4.09 1.72 0.9991 0.9997 0.9955 0.9937 0.9947 0.9934
7 30-Pulse (B) Polygon 1.94 10.61 52.67 3.12 2.27 0.998 0.999 0.995 0.998 0.994 0.997
8 T 1.93 10.48 53.02 2.43 2.04 0.999 0.999 0.996 0.991 0.995 0.991

4.Results and discussion

Fig. 3(a) depicts three groups of 5-phase voltage waveforms with a phase shift of 12o between the same voltages of each group (topology A), and Fig. 3(b) depicts five groups of 3-phase voltaje waveforms with a phase shift of 12o between the same voltajes of each group (topology B). The voltage across the interphase transformer (shown in Fig. 4(a)) has a frequency equal to 3 times that of the supply which results in a significant reduction in volume and cost of magnetics. The 30-pulse converter outputvoltage (shown in Fig. 4(b)) is almost smooth and free of ripplesand its average value is 608.9 V which is approximately equal tothe DC link voltage of a 6-pulse rectifier (607.6 V). This makes the 36-pulse converters suitable for retrofit applications.

Input current waveforms and its harmonic spectrum of the 6-pulse and different 30-pulse converters (polygon(A), hexagon, star, fork, T(A), polygon (B), and, T(B)) extracted and shown in Fig. 5, respectively. The current THD of the device can be assessed in order to check if its harmonic spectrum can contribute to achieve the IEEE 519 limits. These harmonic spectrums are obtained when induction motor operates underlight load (20% of full load) and full load conditions. Obviously, for 6-pulse converter, fifth and seventh order harmonics are dominant. Hence, input current THD of this converter will berelatively a large amount and is equal to 28.53% and 52.53% for full load and light load conditions that are not with in the standard margins. Moreover, the power factor at full load is 0.937, which deteriorates to 0.848 as the load is reduced. These results show that there is a need for improving the power quality at the ac mains using some harmonic mitigators which can easily replacethe existing 6-pulse converter. The supply current wave form along with its harmonic spectrum of fork autotransformer-based30-pulse AC-DC converter at light load and full load is shown in Fig. 5(e), which shows that at full load condition, the THD of the ac mains current is 1.13% and at light load condition, theTHD of the ac mains current is 1.95%. The simulation results of different autotransformer-based 30-pulse AC-DC converterfed DTCIMD are shown in Fig. 5 at full load and light load (20%). Table 1 shows a comparative study of different power-quality indices such as THD of supply current and voltage (THDiand THDv), displacement power factor (DPF), distortion factor (DF), and power factor (PF) of a DTCIMD fed from a 6-pulseconverter and different autotransformer-based 30-pulse converters for different loading conditions. Results show that the input current corresponding to the different autotransformer-based 30-pulse AC-DC converter configuration has an almost unity power factor. The different autotransformer-based 30-pulse AC-DC converters gives the same dc-link voltage as that of a 6-pulse diode bridge rectifier, making it suitable for retrofit applications.

Fig. 3 Autotransformer output voltage in (a) topology A (three groups of 5-phase voltage), and (b) topology B (five groups of 3-phase voltage). 

Fig. 4 (a) Voltage waveform across the interphase transformer and (b) 30-pulse AC-DC converter output voltage.  

Fig. 5 Input current waveform and its harmonic spectrum of (a) sex, (b) polygon (A), (c) hexagon, (d) star, (e) fork, (f) T(A), (g) polygon (B), (h) T(B) autotransformer-based 30-pulse AC-DC converters at light load and full load. 

Furthermore, in the worst case (light loads) the current THD has reached below 4% for the different autotransformer-based 30-pulse AC-DC converters.

5. Apparent power ratings

The apparent power (kVA) ratings of the different autotransformer and tapped IPT, for 36-pulse configuration are calculated using the following Eq. (1):

S=0.5 Vwinding I winding (1)

where V winding is the rms voltage across each part of the autotransformer, and IPT windings and I winding indicates the full loadcurrent of the same windings. These rms values are obtained by simulations of 50 hp (37.3 kW) load as listed in Table 2.

Table 2 Comparison of magnetic rating for 30-pulse converters based on autotransformers. 

Transformer type Main transformer rating (% of load) Interphase reactor rating (% of load) Total magnetic rating (% of load)
Topology A
Polygon(A) 30.5 7.5 38
Hexagon 24.8 5.8 30.6
Star 51.3 7.45 58.75
Fork 43.5 6.4 49.9
T(A) 30.0 6.2 36.2
Topology B
Polygon (B) 43.8 5.6 49.4
T(B) 45.65 6.92 52.57

The calculated ratings are 11,376.5 VA and 2792.5 VA for polygon (A) (topology A) autotransformer and IPT, respectively, which are 30.5% and 7.5% of the load power rating (37.3 kW), respectively. It means that the required magnetic rating of the polygon (A) topology is about 38% of the load rating. The calculated ratings are 9250.4 VA and 2163.4 VA for hexagon autotransformer and IPT, respectively. The ratings of input hexagon autotransformer and IPT are obtained, and these are 24.8%, and 5.8%, respectively of the load rating (37.3 kW).

As mentioned previously, the required magnetic rating of the hexagon topology is 30.6% of the load rating.

The calculated ratings are 19,134.9 VA and 2778.85 VA forstar autotransformer, and IPT, respectively, which are 51.3%and 7.45% of the load power rating (37.3 kW), respectively. It means that the required magnetic rating of the star topology is about 58.75% of the load rating. The calculated ratings are 16,225.5 VA and 2387.2 VA for fork autotransformer, and IPT, respectively, which are 43.5% and 6.4% of the load power rating (37.3 kW), respectively. It means that the required magnetic rating of the fork topology is about 49.9% of the load rating. The calculated ratings are 11,190 VA and 2312.6 VA for T(A) autotransformer, and IPT, respectively, which are 30.0% and 6.2%of the load power rating (37.3 kW), respectively. It means that the required magnetic rating of the T(A) topology is about 36.2%of the load rating.

The calculated ratings are 16,337.4 VA and 2088.8 VA for polygon (B) autotransformer, and IPT, respectively, which are 43.8% and 5.6% of the load power rating (37.3 kW), respectively. It means that the required magnetic rating of the polygon (B) topology is about 49.4% of the load rating. The calculated ratings are 17,027.45 VA and 2581.16 VA for T(B) autotransformer, and IPT, respectively, which are 45.65% and6.92% of the load power rating (37.3 kW), respectively. It means that the required magnetic rating of the T(B) topology is about52.57% of the load rating.

It can also be obtained from simulations that the hexagon 30-pulse harmonic mitigator for retrofit applications needs to taling all the required magnetics of 11.413 kVA, that is to say, only 30.6% of the load power rating. In comparison with the total magnetics ratings of conventional polygon(A) autotransformer-based 30-pulse (38%) and star autotransformer(58.75%), fork autotransformer (49.9%), T(A) autotransformer (36.2%), polygon(B) autotransformer (49.4%), T(B) autotrans-former (52.57%)-based 30-pulse AC-DC converters, the total ratings of magnetics of the hexagon autotransformer 30-pulserectifier system is much less. The low equivalent kVA rating of the hexagon autotransformer has resulted in a system of lower cost compared with other types of autotransformer configuration-based 30-pulse AC-DC converters. The detailed comparison results are tabulated in Table 2.

The T-connected autotransformer configuration requires two single-phase transformers, which is more economical (in weightand volume) as compared with other topologies using three single-phase transformers. It further results in savings in volume, size and finally the cost of the drive. Also, the T(A) 30-pulseharmonic mitigator needs totaling all the required magnetics of13.502 kVA, that is to say, only 36.2% of the load power rating.The low equivalent kVA rating and low weight and volume of the T(A) autotransformer has resulted in a system of lower volume, weight, losses and cost compared with other types of autotransformer configuration-based 30-pulse AC-DC converters.

6. Conclusions

The different 30-pulse AC-DC converters are capable of eliminating up to 27th harmonics in the input supply current.The different rectifier has the flexibility to vary the dc link voltage, simply by changing the ratio of number of turns of the transformer, which makes it suitable for retrofit applications.The simulation results have shown that the THD of input current remains below 4.0% and the power factor is always above0.99 in the wide operating range of the loads to the different autotransformer-based 30-pulse AC-DC converter configuration.

Results show that even under load variations, the fork autotransformer-based 30-pulse converter has an improved performance and the current THD is always less than 2% for allloading conditions. The low equivalent kVA rating (30.6%) of the hexagon autotransformer has resulted in a system of lower cost compared with other types of autotransformer configuration-based 30-pulse AC-DC converters. As well asthe low equivalent kVA rating (36.2%) and low weight and volume of the T(A) autotransformer has resulted in a system of lower volume, weight, losses and cost compared with other types of autotransformer configuration-based 30-pulse AC-DC converters.

References

Abdollahi, R. (2012a). Hexagon-connected transformer-based 20-Pulse AC-DC converter for power quality improvement. Journal of Electrical Systems,8(2), 119-131. [ Links ]

Abdollahi, R. (2012b). 30-pulse AC-DC converter for power quality improvement in direct torque controlled induction. International Journal of Power Electronics Converter (IJPEC), 1(1). [ Links ]

Abdollahi, R. (2012c). A novel T-connected autotransformer based 30-pulseAC-DC converter for power quality improvement. International Journal of Emerging Sciences, 2(1), 87-103. [ Links ]

Abdollahi, R. (2012d). Study of delta/polygon-connected transformer-based 36-pulse ac-dc converter for power quality improvement. Archives of Electrical Engineering, 61(2), 277-292. [ Links ]

Abdollahi, R. (2012e). Delta/fork-connected transformer-based 36-pulse AC-DC converter for power quality improvement. Journal of Electrical andControl Engineering, 2(2), 20-26. [ Links ]

Abdollahi, R. (2012f). A tapped delta autotransformer based 36-Pulse AC-DC converter for power quality improvement. International Journal of Electricaland Electronics Engineering Research (IJEEER), 2(1), 31-53. [ Links ]

Abdollahi, R. (2012g). T-connected autotransformer based 36-pulse AC-DC converter for power quality improvement. Przeglad Elektrotechniczny,88(2), 321-327. [ Links ]

Abdollahi, R. (2012h). Pulse doubling in zigzag-connected autotransformer-based 12-pulse ac-dc converter for power quality improvement. Journal of Electrical Engineering, 63(6), 357-364. [ Links ]

Abdollahi, R. (2015a). Double zigzag-connected autotransformer-based24-pulse AC-DC converter for power quality improvement. Science International (Lahore), 27(2), 1035-1040. [ Links ]

Abdollahi, R. (2015b). Harmonic mitigation using 36-pulse AC-DC converter for direct torque controlled induction motor drives. Journal of Applied Research and Technology, 13(1), 135-144. [ Links ]

Abdollahi, R. (2015c). Design and construction of a polygon-connected autotransformer-based 36-pulse AC-DC converter for power quality improvement in retrofit applications. Bulletin of the Polish Academy of Sciences Technical Sciences, 63(2), 353-362. [ Links ]

Abdollahi, R., & Jalilian, A. (2011). Application of pulse doubling in star-connected autotransformer based 12-pulse AC-DC converter for power quality improvement. International Journal of Electrical and Electronics Engineering, 5(4). [ Links ]

Abdollahi, R., & Jalilian, A. (2012a). Fork-connected autotransformer based30-pulse AC-DC converter for power quality improvement. International Journal on Electrical Engineering and Informatics, 4(2), 202. [ Links ]

Abdollahi, R., & Jalilian, A. (2012b). Application of pulse doubling in hexagon-connected transformer-based 20-pulse AC-DC converter for power quality improvement. Przegl˛ad Elektrotechniczny (Electrical Review), 88(10A),153-161. [ Links ]

Bose, B. K. (1998). Modern power electronics and AC drives. Singapore: Pearson Education. [ Links ]

IEC Standard 61000-3-2:2004. (2004). Limits for harmonic current emissions. International Electromechanical Commission. Geneva. [ Links ]

IEEE Standard 519-2014. (2014). Recommended practices and requirements for harmonic control in electrical power systems. New York: IEEE Inc. [ Links ]

Paice, D. A. (1996). Power electronic converter harmonics: Multipulse methods for clean power. New York: IEEE Press. [ Links ]

Singh, B., Bhuvaneswari, G., & Garg, V. (2006a). T-connected autotransformer-based 24-pulse AC-DC converter for variable frequency induction motor drives. IEEE Transactions on Energy Conversion, 21(3), 663-672. [ Links ]

Singh, B., Bhuvaneswari, G., & Garg, V. (2006b). Reduced rating T-connected autotransformer based thirty-pulse AC-DC converter for vector controlled induction motor drives. Journal of Power Electronics, 6(3), 214-225. [ Links ]

Singh, B., Bhuvaneswari, G., Garg, V., & Chandra, A. (2006). Star connected autotransformer based 30-pulse AC-DC converter for power quality improvement in vector controlled induction motor drives. In Power India conference (pp. 6). IEEE. [ Links ]

Singh, B., Garg, V., & Bhuvaneswari, G. (2006). Polygon connected 15-phaseAC-DC converter for power quality improvement. In Proc. IEEE Conf. Power Electronics, Drives and Energy Systems (PEDES ‘06). [ Links ]

Singh, B., Bhuvaneswari, G., & Garg, V. (2007a). An improved power-quality30-pulse AC-DC for varying loads. IEEE Transactions on Power Delivery,22(2), 1179-1187. [ Links ]

Singh, B., Bhuvaneswari, G., & Garg, V. (2007b). Harmonic mitigation in AC-DC converters for vector controlled induction motor drives. IEEE Transactions on Energy Conversion, 22(3), 637-646. [ Links ]

Singh, B., Bhuvaneswari, G., & Garg, V. (2007c). A novel polygon based 18-pulse AC-DC converter for vector controlled induction motor drives. IEEE Transactions on Power Electronics, 22(2), 488-497. [ Links ]

Singh, B., Garg, V., & Bhuvaneswari, G. (2007). A novel T-connected autotransformer-based 18-pulse AC-DC converter for harmonic mitigation in adjustable-speed induction-motor drives. IEEE Transactions on Industrial Electronics, 54(5), 2500-2511. [ Links ]

Singh, B., & Gairola, S. (2007). Design and development of a 36-pulse AC-DC converter for vector controlled induction motor drive. In Proc. IEEE Conf. Power Electron. Drives Syst. PEDS’07 (pp. 694-701). [ Links ]

Appendix A.

Three-phase squirrel cage induction motor-50 hp(37.3 kW), three phase, four pole, Y-connected, 460 V,60 Hz. R s= 0.0148 Ω; R r= 0.0092 Ω; X ls= 1.14 Ω; X lr= 1.14 Ω, X Lm= 3.94 Ω, J = 3.1 kg m2.

Controller parameters: PI controller K p= 300; K i= 2000.DC link parameters: L d= 2 mH; C d= 3200 μF.Source impedance: Z s= j0.1884 Ω (=3%).

Received: July 25, 2015; Accepted: December 09, 2016

*E-mail address:rohollah.abdollahi@yahoo.com

Peer Review under the responsibility of Universidad Nacional Autónoma de México.

Conflict of interest The authors have no conflict of interest to declare.

Creative Commons License This is an open-access article distributed under the terms of the Creative Commons Attribution License