SciELO - Scientific Electronic Library Online

 
vol.13 issue4Frequency of nasal and nasopharyngeal alterations in patients with maxillary constriction and vertical facial growthIn vitro study: three dentin conditioners to evaluate the opening of dentine tubules in root canals author indexsubject indexsearch form
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Revista odontológica mexicana

Print version ISSN 1870-199X

Abstract

VENEGAS LANCON, Rogelio Danovan; SOLORZANO LEMUS, Fernando; MORENO MALDONADO, Víctor  and  LOPEZ MORALES, Salvador. Influence of the polymerizing cycle on the monomer concentration of three commercial resins for denture base. Rev. Odont. Mex [online]. 2009, vol.13, n.4, pp.205-216. ISSN 1870-199X.  https://doi.org/10.22201/fo.1870199xp.2009.13.4.15556.

Materials used in the elaboration of complete dentures have instructions for their correct use; however they are not followed properly, producing alterations in the residual monomer concentration.

Objective

The main objective was to demonstrate the importance of the relation between time and polymerization temperature (Polymerization Cycle) on the residual monomer concentration of the heat polymerized acrylic resins used in the elaboration of denture bases.

Methods

For quantification and analysis of residual monomer 3 discs of every commercial acrylic resin were made, according to manufacturers' instructions (9 discs). Those were analyzed by Gas Chromatography (GC) for the quantification of the residual monomer concentration. Also, 3 discs of every acrylic resin applying three different polymerization cycles were made: conventional method M1, short-term terminal boiled M2 and long-term terminal boiled M3 (27 discs), to be analyzed by Gas Chromatography for the quantification of the residual monomer concentration.

Results

The analysis showed that the resin Acriethil® MMR was 0.3780%, while the resin Nictone® has the lowest percentage, reaching a value of 0.0482% of MMR and resin-45 High Impact Denture Acrylic® has the highest percentage of residual monomer produces a value of 0.5770%. While analyzing the results from the three different polymerization cycles applied, a significant change from the residual monomer concentration on both acrylic resins analyzed was observed.

Conclusions

The three acrylic denture base resins analyzed in this research fulfill the residual monomer concentration established by ISO 1567:1999 with success to be handled under the manufacturer conditions. But if the polymerization cycle is changed, alterations of the residual monomer concentration will be obtained.

Keywords : Chromatographic column; gas chromatography; chromatogram; elution; methylmethacrylate; monomer; residual methyl-methacrylate; poly (methyl methacrylate); acrylic resins.

        · abstract in Spanish     · text in Spanish