SciELO - Scientific Electronic Library Online

 
vol.10 issue3Critical analysis and innovation proposals to the heat and thermal shock test method of the Brazilian Standard NBR 15575 (2013) author indexsubject indexsearch form
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Revista ALCONPAT

On-line version ISSN 2007-6835

Abstract

SILVA, W. W.  and  MONTEIRO, E. C. B.. The pathological manifestations and risks of the protectors of air conditioners in buildings. Rev. ALCONPAT [online]. 2020, vol.10, n.3, pp.377-393.  Epub June 06, 2022. ISSN 2007-6835.  https://doi.org/10.21041/ra.v10i3.410.

Faced with the large number of partial or total collapses in buildings, the objective of this study is the identification of the pathological manifestations and the risks of the supports for air conditioners of reinforced concrete in the buildings. The data were collected by 3D software and consolidated in the field. Of the 61 buildings analyzed, 48% are of the window model which, in a situation of degradation and fall, can reach the ground with an impact of the order of tons. In coastal regions, we add the accelerating effects of the corrosion of the reinforcement, such as high humidity, pollution by automotive vehicles and marine region. It was concluded that these supports do not have adequate structural designs, allied to the low quality and accelerating effects of the reinforcement corrosion, rendering them not recoverable.

Keywords : pathology; corrosion; air conditioning; concrete; risks.

        · abstract in Portuguese | Spanish     · text in English | Portuguese | Spanish