SciELO - Scientific Electronic Library Online

 
vol.12 issue1Influence of the void ratio of cellular concrete on the corrosion of steel reinforcementThermographic study of the pathological manifestations due to humidity and of the conservation state of the Santa Maria Basilica’s roof author indexsubject indexsearch form
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Revista ALCONPAT

On-line version ISSN 2007-6835

Abstract

BRICENO-MENA, J. A.  and  CASTRO-BORGES, P.. Practical use of the safety factor in the column repair strategy of a concrete building with historical value. Rev. ALCONPAT [online]. 2022, vol.12, n.1, pp.98-109.  Epub Feb 23, 2024. ISSN 2007-6835.  https://doi.org/10.21041/ra.v12i1.569.

In this paper the practical use of the safety factor (FS) in the column repair strategy of a reinforced concrete building with historical value (almost 70 years) is presented. 80% of a building located in the historic center of the city of Campeche, Mexico, declared a World Heritage Site by UNESCO, was repaired. Strategies were used for a better use of material resources, equipment, and labor in the repair of walls, columns, slabs, and beams. One of the strategies was to use the theoretical FS to calculate the repair depth without structural consequences but fulfilling the purpose of controlling the carbonation of the concrete and maintaining the desired prediction of service life.

Keywords : repair; reinforced concrete; durability; security factor.

        · abstract in Portuguese | Spanish     · text in English | Portuguese | Spanish     · English ( pdf ) | Spanish ( pdf ) | Portuguese ( pdf )