SciELO - Scientific Electronic Library Online

 
vol.83 issue3Prevalence of Vitamin D deficiency and associated factors in Mexican patients with allergic rhinitis and asthmaBenign cystic adenomatoid malformation: A case report and literature review author indexsubject indexsearch form
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Revista médica del Hospital General de México

On-line version ISSN 2524-177XPrint version ISSN 0185-1063

Abstract

BAEZ-SALDANA, Renata et al. Accuracy of the tuberculin skin test for diagnosis of latent tuberculosis in population with high coverage of Bacillus Calmette–Guérin vaccination. Rev. med. Hosp. Gen. Méx. [online]. 2020, vol.83, n.3, pp.120-126.  Epub Sep 06, 2021. ISSN 2524-177X.  https://doi.org/10.24875/hgmx.20000086.

Introduction:

The Mantoux tuberculin skin test (TST) for the diagnosis of latent tuberculosis infection (LTBI) has a variable performance and limited usefulness in Bacillus Calmette–Guérin (BCG)-vaccinated populations.

Objective:

The objective of the study was to evaluate the performance of the TST for the diagnosis of LTBI in household contacts of patients with active pulmonary tuberculosis (PTB).

Materials and methods:

The TST was administered to 113 cases with PTB and 194 household contacts. The gold standard was the bacteriological confirmation in patients. The household contacts were classified as true positives according to the selected cutoff point. Those with purified protein derivative reactivity less than the cutoff point but different from zero were classified as false positives. The area under the curve was measured and the best cutoff point was determined. Sensitivity, specificity, positive and negative predictive values (PV), and positive and negative likelihood ratios (LR) were measured with 2 × 2 contingency tables.

Results:

The best cutoff point was at 10 mm of induration, with an area under the curve of 0.93, sensitivity 85%, specificity 88%, positive PV 94%, negative PV 71%, positive LR 6.9, and negative LR 0.17. There was no association between reactivity to TST and BCG vaccination, OR (95% confidence interval CI) 1.14 (0.65-2.10), p = 0.644.

Conclusions:

The TST showed a very good performance, as it lead to an important change from pre-test to post-test probability.

Keywords : Latent tuberculosis; Tuberculin skin test; Specificity; Bacillus Calmette–Guérin vaccination.

        · text in English