Services on Demand
Journal
Article
Indicators
Cited by SciELO
Access statistics
Related links
Similars in SciELO
Share
Revista de ciencias tecnológicas
On-line version ISSN 2594-1925
Abstract
HERNANDEZ RODRIGUEZ, Luis Tinerfe; CEVALLOS LOPEZ, María José; MERA VERA, Jorge André and GUAMINGA PILLAJO, Edwin Eduardo. Analysis of angle type shear connectors in steel and concrete composite beams. Rev. cienc. tecnol. [online]. 2023, vol.6, n.3, e262. Epub June 25, 2024. ISSN 2594-1925. https://doi.org/10.37636/recit.v6n3e262.
Because there is no standardized calculation formula for angle-type connectors and they can be used in steel and concrete composite beams, this work aimed to analyze the shear resistance of 3mm vertically welded angle profiles with two different types of orientations. For this, 14 test specimens were made, 7 containing connectors with 45° orientations and another seven at 90°; these test specimens were subjected to push-out tests, obtaining load-slip data, which were treated statistically to be later used in behavior analysis of the connectors. Parameters such as strength, ductility, rigidity, and failure modes were analyzed. The failure mode that prevailed in all the test tubes was the fractionation in the entire width of the concrete; in terms of ductility, connectors with a 45° orientation are considered malleable according to the Eurocode. In addition, the characteristic stiffness is greater for connectors with a 90° orientation; These parameters were compared in both types of connectors, and it was concluded that those with a 90° orientation have higher resistance. Therefore, they are the most suitable for use in construction.
Keywords : Shear connector; Push-out test; Composite structures.