Introduction
The red-lored parrot (Amazona autumnalis, order Psittaciformes) measures 32-35.5 cm in length, weighs between 314 and 485 grams, and has a life span of 20 to 60 years. It has bright green plumage, a red forehead, a blue crown, and yellow cheeks. This species can be found in Brazil, Colombia, Ecuador, Mexico, Panama and Venezuela, and it is currently listed in the Appendix II of CITES.1
Ophthalmological examination in birds are similar to those in mammals, and generally follow a complete physical assessment and an extensive clinical history.2 However, eye diseases are often sub-diagnosed in bird species, partly due to limited diagnostic methods and lack of reference data. Determination of tear flow should be routinely included test in any eye examination.3
Several ocular problems and diseases have been reported in psittacine birds, including peri-orbital lesions,4 bilateral supra-orbital abscesses,2 corneo-conjunctival dermoid cysts,5 blepharo-conjunctivitis due to staphylococci, and fungal keratitis.2 Also, exophthalmos secondary to squamous cell carcinoma in the infraorbital sinus has been found in an eclectus parrot (Eclectus roratus solomonensis)6 or secondary to retrobulbar adenoma in an African gray parrot (Psittacus erithacus).7 A periorbital liposarcoma has also been diagnosed for this last species.8
The Schirmer tear test strips can be used for tear flow measurement in birds, but reference data is limited for most species that are usually taken for consultation. Also, placement of strips in the bottom of the conjunctival sac of birds can prove to be difficult. Tear flow reference values for Red-lored parrots (Amazona autumnalis) are nonexistent. However, reference data can be found for larger parrots, such as the African gray parrots (Psittacus erithacus, 8 ± 1.5 mm/min), and for smaller species, such as lories and conures (4.5 ± 1 mm/min).9 Ophthalmic parameters have also been described in ostriches (Struthio camelus),10 anseriformes,11 blue macaws (Ara ararauna),12 yacos (Psittacus erithacus), eclectic parrots (Eclectus roratus) and parrots of the genus Pionus,13 as well as in pigeons (Columba spp.).14
Paper tips that are commonly used for endodontic procedures, have a high absorptive capacity and a conical shape that may be better suited for measurement of tear flow in eyes of birds.15 They are also cheaper than Schirmer strips and are readily available, hence being a potential alternative to measure tear flow in this and other bird species.
The Red-lored parrot is a commonly kept pet in Mexico, and ophthalmic reference values need to be established for use in routine clinical examinations that involve eye inspection.
Material and methods
For this study 26 captive adult red-lored parrots (Amazona autumnalis) of undetermined sex, were used. Birds were housed in groups at “El Nido” aviary located in Ixtapaluca, State of Mexico. Environmental conditions and diets were similar for all animals. Parrots were deemed healthy by remote and physical examinations, where mental state, heart rate, respiratory rate, temperature, color of the cloacal mucosa, and body condition were determined. All birds with signs of disease or abnormalities in eyes or periocular regions were excluded from the study.
Birds were briefly restrained in two consecutive days to measure tear flow. A physical examination was also performed during the first day, and no sedation was used. During the second day, intranasal midazolam was administered as a sedative agent, and care was taken to measure tear flow only after sedation effects had been confirmed.
TearFloTM test strips
Tear flow was assessed in each eye by placing a strip in the bottom of the conjunctival sac for 60 seconds. The strip was then removed, and the wet segment immediately measured, using the printed metric scale for test interpretation (Figure 1).
ABC Dental® # 30 colored paper tips
As for the TearFlo strips, endodontic paper tips were placed in the ventral fornix of the inferior eyelid of each eye for 60 seconds, then removed and the wet segment immediately measured using a caliper to determine tear flow (Figure 2).16
Statistical analysis
Differences in tear flow were analyzed by ANOVA with JMP statistical software (SAS). The fixed variables were measuring method (Schrimer strips or endodontic tips), eye (left or right), sedation, and their interactions up to the second order. The parrot was considered as a random variable. To calculate the F statistic for the fixed effects and their first order interactions, the error term was the interaction between said fixed variable(s) and the random variable. For higher order interactions the residual error of the model was used.17
Results and discussion
Tear production seems to be related to the size of eye orbits and tissue of lacrimal glands, hence imposing a challenge and denoting an absence of reference values for a wide range of bird species.2 This shortcoming is usually handled in daily practice by using a second (clinically normal) bird of the same species, and preferably the same household, to compare values of interest, that could help detect ophthalmic alterations.2 Nonetheless, establishment of reference values for clinical practice is imperative.
Endodontic paper points have not been standardized for measurement of tear flow. However, their use for this purpose has been previously assessed in birds,16 marmoset monkeys,14 rabbits18 and cats.19 Differences in brands, sizes and specific characteristics of paper tips, such as trabecular density or type of cellulose fiber should be considered to determine efficiency and to establish appropriate reference values.20 Use of paper tips for tear flow measurement was found to be cheaper than Schirmer strips in this study, representing nearly 3% of the cost.
Placement of both Schirmer strips and paper tips in the bottom of the conjunctival sac proved to be difficult in this study, since the nictitating membranes moved repeatedly, constantly dislodging the strip during measurement of tear flow. This difficulty was also reported by Falcão et al when making measurements of tear flow with Schirmer strips in macaws.3 The correct restraining of a bird is certainly important to accomplish an adequate measurement, since improper handling causes stress on the bird, which can lead to more difficulty in placing and keeping the strips in the correct position, resulting in a faulty tear flow measurement, that could lead to erroneous results. Lange et al indicated a further complexity for the use of this technique in marmoset monkeys (Callitrhrix penicillata), since two people were needed (one to restrain the animal and one to place the strip) for adequate tear flow measurement in this species.14 However, placement of paper strips in the bottom of the conjunctival sac of marmoset monkeys did not appear to be as hard comparatively, allowing a decreased waste of tips and often accomplishing measurement on the first try.
Results of this study indicate that both TearFlow test strips and ABC dental #30 paper tips are viable methods for measurement of tear flow in Red-lored parrots. No difference was found in average tear flow between methods (p=0.3629; Table 1). Average tear flow was also found to be similar for both eyes (p = 0.7597; Table 2). Observed tear flow values per eye were of 0.6365 cm/min using the Tear FloTM Strip test, and of 0.5942 cm/min using the ABC Dental® # 30 colored paper tips (Table 1). Storey et al found similar results (7.9 ± 2.6 mm/min) when measuring tear flow in Amazona ventralis with the Schirmer test.21 However, Monção et al reported a tear production of 14.9 ± 1.6 mm/min and 13.1 ± 1.4 mm/min in captive Amazona amazona and Amazona aestiva respectively, when using absorbent paper tips.16 This difference in tear flow measurements with the results of this study when using the endodontic tip technique could be due to specific characteristics of tips used, as mentioned by Lima et al20 and Pumarola et al18 Also, even if minimal, the degree of corneal and/or conjunctival irritation caused by differences in tips used could have affected tear flow.18,20 In addition, observed differences in tear flow could have been influenced by environmental conditions, since eye moisture is reduced when animals are exposed to dry environments (64-76% humidity levels in the Monção et al study vs 38-58% humidity for this study).19,22
Measurement method | Tear flow (cm/min) | Standard Error |
Tear FloTM Test Strips | 0.6365 | 0.0322 |
ABC Dental® # 30 Colored paper tips | 0.5942 | 0.0322 |
The use of intranasal midazolam to sedate birds can have minimal cardiopulmonary effects.23 Also, the low pH of midazolam (3.0-3.5) can induce a burning eye sensation and lacrimation.24 Moreover, children can develop nasal congestion, nasopharyngeal irritation and bad taste after intranasal midazolam administration.25 This sedative may also induce sneezing in dogs26 and psittacines (Amazona aestiva and Amazona amazonica)27 when administered intranasally. Lacrimation was observed after the administration of midazolam in only one of the 26 assessed birds in this study, and sedation did not affect tear flow values (p=0.9329). Hence, midazolam can be used to facilitate handling of birds and placement of paper strips, without affecting tear flow values, independently of technique used. There were no significant interactions between the studied variables (p> 0.05)
Conclusions
This study provides tear flow reference values for clinical use in the Amazona autumanlis species.
Endodontic tips can potentially be used for tear flow measurement in several species (especially in those having smaller eyes). This technique is also more cost-effective than the Schirmer strip test.
This study stresses the need to establish species specific ophthalmic reference values for clinical practice in birds, since differences have been reported even in specimens within the same genus.