Servicios Personalizados
Revista
Articulo
Indicadores
Links relacionados
- Similares en SciELO
Compartir
Revista de investigación clínica
versión On-line ISSN 2564-8896versión impresa ISSN 0034-8376
Resumen
GARCIA-OSOGOBIO, Sandra Minerva et al. Single layer colonic anastomoses using maxon vs. two layer anastomoses using chromic catgut and silk: structured abstract. Rev. invest. clín. [online]. 2006, vol.58, n.3, pp.198-203. ISSN 2564-8896.
Background. The safety of an intestinal anastomosis is usually measured by its complication rate, especially the incidence of anastomotic leakage. A wide variety of methods have been described to reestablish intestinal continuity including single-layer continuous or two-layer interrupted anastomosis. Objectives. To evaluate if the single-layer continuous anastomosis using polygluconate is safer and reliable than two-layer interrupted anastomosis with chromic catgut and silk. Material and methods. A prospective, experimental, randomized and comparative analysis was conducted in 20 dogs. They were divided in two groups; group 1 underwent two-layer interrupted anastomosis and group 2 underwent sigle-layer continuous technique. Anastomoses were timed. Both groups were under observation. Anastomotic leakage, and other complications were evaluated. The animals were sacrified and the anastomosis was taken out together with 10 cm of colon on both sides of the anastomosis. Breaking strength, histologic evaluation and hydroxyproline determination were performed. Results. Ten two-layer anastomosis and ten single-layer anastomosis were performed. A median of 25 minutes (range: 20-30 minutes) was required to construct the anastomoses in group 1 versus 20 minutes (range: 12-25 minutes) in group 2. All animals survived and no leakage was observed. Wound infection ocurred in four dogs (20%). Median breaking strength was 230 mm Hg in group 1 and 210 mm Hg in group 2. Hydroxyproline concentration was 8.94 mg/g in group 1 (range: 5.33-16.71) and 9.94 mg/g in group 2 (range: 2.96-21.87). There was no difference among groups about the inflammatory response evaluated by pathology. There was no statistical significance in any variable evaluated. Conclusions. This study demonstrates that a single-layer continuous is similar in terms of safety to the two-layer technique, but because of its facility to perform, the single-layer technique could be superior.
Palabras llave : Single layer anastomosis; Two layer anastomosis; Breaking strength; Hydroxyproline.