vol.35 número2MODELOS DE CALIBRACIÓN PARA LA CUANTIFICACIÓN ESPECTROFOTOMÉTRICA DE HIDROCARBUROS TOTALES DEL PETRÓLEO EN SUELOVARIACIÓN DE LOS NIVELES DE BUTIRILCOLINESTERASA DE UNA POBLACIÓN MEXICANA EN DISTINTOS PERIODOS DE CONTROL DE Aedes SPP. índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • No hay artículos similaresSimilares en SciELO

Compartir


Revista internacional de contaminación ambiental

versión impresa ISSN 0188-4999

Resumen

CRUZ-HERNANDEZ, Yusniel; VILLALOBOS, Mario; GONZALEZ-CHAVEZ, José Luz  y  MARTINEZ-VILLEGAS, Nadia. OPTIMIZING THE DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY METHOD WITH A HANGING MERCURY ELECTRODE FOR THALLIUM (I) DETERMINATION IN THE PRESENCE OF LEAD (II) AND COPPER (II) FOR APPLICATION IN CONTAMINATED SOILS. Rev. Int. Contam. Ambient [online]. 2019, vol.35, n.2, pp.481-494.  Epub 19-Feb-2020. ISSN 0188-4999.  https://doi.org/10.20937/rica.2019.35.02.18.

The conditions that allow thallium (I) determination in the presence of lead (II) and copper (II) were optimized without prior separation of these cations, using a previously developed differential pulse anodic stripping voltammetry (DPASV) method, with a hanging mercury drop working electrode (HMDE) and a Ag/AgCl reference electrode. Unfortunately, the electrochemical activity of lead (II) interferes with this determination, but the addition of 0.1 M EDTA complexing agent (at pH = 4.6) causes a shift in the Pb(II) peak to more negative values, making it possible to quantify Tl(I) in its presence at an optimal deposition potential of -0.550 V. However, the Cu(II) reduction peak, which is normally found far away from that of Tl(I), is also shifted when complexed with EDTA, approaching the Tl(I) peak and becoming an interfering ion. The deposition time and scan rate that were found optimal for the determination were 30 s and 10 mV/s, respectively. Under these conditions it was found that maximum concentration ratios for Pb(II)/Tl(I) and Cu(II)/Tl(I) of 2000 and 400, respectively, did not show interference thus duplicating and quadruplicating the concentrations of Pb(II) and Cu(II), respectively above which interference with Tl(I) occurs, as compared to the standard method published. The proposed methodology has a detection limit of 2 μg/L, a quantification limit of 7 μg/L, and a linear range between 2.3 and 20 μg/L. Enriched Tl solutions of 0.5, 2.5 and 9 μg/L showed excellent recoveries. The methodology was applied to extractions of contaminated soil samples with Tl contents from 0.05 to 3.2 mg/kg.

Palabras llave : voltamperometric; interference; trace analysis; thallium; EDTA; soil samples.