vol.37 número1Impacto del programa “Enhanced Recovery After Surgery” en artroplastía de rodilla a nivel institucionalEvaluación funcional y de calidad de vida en el seguimiento de pacientes con artropatía de Charcot tratados mediante artrodesis de tobillo con clavo centromedular retrógrado bloqueado índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • No hay artículos similaresSimilares en SciELO

Compartir


Acta ortopédica mexicana

versión impresa ISSN 2306-4102

Resumen

GODOY-MONZON, D et al. Preliminary results of hybrid fixation modular implant in revision knee arthroplasty. Acta ortop. mex [online]. 2023, vol.37, n.1, pp.19-24.  Epub 11-Mar-2024. ISSN 2306-4102.  https://doi.org/10.35366/112809.

Introduction:

revision total knee arthroplasty (TKA) is a challenging procedure that requires proper alignment, restoration of bone loss, and prevention of instability. Modern revision systems offer progressive implant constriction with multiple options for offset, augmentation, and fixation stems.

Objective:

to evaluate the clinical outcomes of a modular implant with hybrid fixation in revision TKA with a minimum follow-up of two years.

Material and methods:

we retrospectively included all revision TKA surgeries performed between September 2018 and September 2019, using the same implant. Patient demographics, comorbidities, and data on bone defects were recorded. Clinical outcomes were assessed using subjective roles and Maudsley scores and the Knee Society Score (KSS). Complications during follow-up were also documented.

Results:

a total of 23 patients were analyzed, comprising 65% females and 35% males, with a median age of 71.1 years. Bone defects following implant removal were classified as F2.T2 in 39.13% of cases, F1.T2 in 8.69%, and F1.T1 in the remaining 52.17%. There were significant improvements in the KSS score (preoperative: 53 points, postoperative: 79 points; p < 0.001). Three (13%) complications were reported, two of which were directly related to the surgery, and two patients required subsequent revision surgery. The 2-year survival rate was 91.3%.

Conclusion:

the use of a modular implant with hybrid fixation in revision TKA demonstrated a high 2-year survival rate, significant improvements in clinical scores, and a low incidence of short-term complications. These findings support the efficacy and safety of this approach, providing favorable clinical outcomes and high patient satisfaction.

Palabras llave : revision surgery; total knee replacement; modular implants.

        · resumen en Español     · texto en Español