Servicios Personalizados
Revista
Articulo
Indicadores
Citado por SciELO
Accesos
Links relacionados
Similares en SciELO
Compartir
Revista odontológica mexicana
versión impresa ISSN 1870-199X
Resumen
JIMENEZ SUAREZ, María José; SANDOVAL VERNIMMEN, Fernando y RODRIGUEZ MERCHAN, Estefanía Alexandra. Comparison of marginal fit of zirconia copings manufactured with the use of two CAD/CAM systems Cerec InLab (Sirona ® ) CAD/CAM Zirkonzahn (Zirkonzahn ® ) and Zirkograph 025 ECO pantographic system (manual milling system) (Zirkonzahn ® ). Rev. Odont. Mex [online]. 2015, vol.19, n.4, pp.240-245. ISSN 1870-199X. https://doi.org/10.1016/j.rodmex.2015.10.005.
Objective:
To compare marginal fit of zirconia copings manufactured following two different systems: CAD/CAM Cerec InLab (Sirona®) and Zirkonzahn (Zirkonzahn®) as well as a Zirkograph 025 ECO (Zirkonzahn®) pantograph system.
Material and methods:
A master Cr-Co model stump was manufactured; it was prepared for the zirconia crown of an upper premolar. Ten zirconia copings were manufactured for each group following manufacturer¿s instructions. Control group consisted on ten metallic copings. A replication technique was followed using elite HD+ polyvinyl siloxane (Zhermack®). Measurements were taken using a stereomicroscope at 50x magnification so as to obtain marginal width in microns and thus determine absolute marginal discrepancy of each coping. Statistical analysis was conducted using IBM SPSS® software. T-test study was conducted in order to compare obtained data.
Results:
Mean marginal absolute discrepancy and marginal width were as follows: 92.14 ± 38.59 and 78.62 ± 31.33 μm for Cerec InLab (Sirona®) CAD/CAM system, 38.71 ± 12.62 and 36.91 ± 13.56 μm for Zirkonzahn (Zirkonzahn®) CAD/CAM system, 77.92 ± 38.01 and 69.42 ± 33.23 μm for Zirkograph 025 ECO (Zirkonzahn®) pantograph system. Control group made of metal copings exhibited 44.11 ± 15.36 and 43.74 ± 15.70 μm. With respect to absolute marginal discrepancy and marginal width, significant differences were observed when comparing Cerec InLab (Sirona®) and Zirkograph 025 ECO (Zirkonzahn®) with control group. Nevertheless, no significant differences were observed between Zirkonzahn (Zirkonzahn®) CAD/CAM system and the control group. Overall level of statistical significance was p > 0.001.
Conclusions:
Zirkonzahn® CAD/CAM system was the most accurate system of all. CAD/CAM Cerec InLab system (Sirona®) proved to be the less precise system.
Palabras llave : CAD/CAM; marginal discrepancy; zirconia; pantograph (milling) systems.