Serviços Personalizados
Journal
Artigo
Indicadores
- Citado por SciELO
- Acessos
Links relacionados
- Similares em SciELO
Compartilhar
Gaceta médica de México
versão On-line ISSN 2696-1288versão impressa ISSN 0016-3813
Resumo
GARCIA-VILLARREAL, Ovidio Alberto. Long-term effectiveness of the Cox-maze III procedure and its relationship with left atrial postoperative size. Gac. Méd. Méx [online]. 2019, vol.155, n.6, pp.590-595. Epub 25-Out-2021. ISSN 2696-1288. https://doi.org/10.24875/gmm.19005385.
Introduction:
The cox-maze III procedure is designed to eliminate atrial fibrillation (AF).
Objective:
To determine the relationship of left atrial (LA) postoperative size after undergoing the Cox-maze III procedure.
Method:
From July 2012 to April 2016, 50 patients with primary mitral valve disease and concomitant AF were operated on. A "cut-and-sew" cox-maze III procedure with a full biatrial lesion pattern was used. AF preoperative duration was 3.5 ± 2.1 years.
Results:
There was no operative mortality. Freedom from AF was 92%, 88% and 73.7% at three months and at one and 3 years, respectively. A direct relationship was found between LA postoperative size and the probability of cox-maze failure when LA is > 6.5 cm at one year (relative risk [RR] = 10.5; 95% confidence interval [CI]:4.30-26.67, p < 0.0001) and at 3 years (RR = 27.1; 95% CI: 3.87-189.86, p = 0.0009). LA size decreased from 7.1 ± 0.5 cm to 6.2 ± 0.5 cm (p < 0.0001).
Conclusions:
The cox-maze III procedure is efficacious for eliminating mitral valve disease-associated AF when LA postoperative size is ≤ 6.5 cm.
Palavras-chave : Atrium; Arrhythmia; Atrial fibrillation; Maze procedure; Mitral valve.