SciELO - Scientific Electronic Library Online

 
vol.76 número4Regresión tardía de la estenosis intrastentFactores de riesgo cardiovascular en una muestra de mujeres jóvenes mexicanas índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Archivos de cardiología de México

versão On-line ISSN 1665-1731versão impressa ISSN 1405-9940

Resumo

SOTOMAYOR GONZALEZ, Arturo et al. Non-invasive assessment of endothelial function. Intra and inter-observer variability. Arch. Cardiol. Méx. [online]. 2006, vol.76, n.4, pp.397-400. ISSN 1665-1731.

Background and objectives: Non-invasive evaluation of endothelial function with high resolution ultrasound has become a widely accepted tool in determination of high risk subjects for early atherosclerosis. Despite its simple appearance, ultrasonographic assessment of brachial artery changes, is technically challenging and has a significant learning curve. In the present study, we evaluate the intra and inter-observer variability in assessing peripheral endothelial function with high resolution ultrasound at a tertiary referral center. Methods: Assessment of endothelial function was performed by 2 physicians in 20 volunteers without evidence of coronary artery disease. Endothelial function is evaluated with a high frequency bidimensional ultrasound with a 10.0-MHz linear-array transducer used for the study. Each volunteer was examined by both observers using an identical protocol, measuring brachial artery diameter on three occasions. Results: Excellent correlation was observed for all brachial artery measures with a Spearman's correlation coefficient > 0.9 (p < 0.0001). Flow-mediated dilation (FMD) in the study population was of 10.45 ± 6.9%. Flow independent dilation (FID) was of 24.35 ± 7.63%. Intra-observer variability was of 2.1 % for observer A and 1.1 % for observer B. Conclusions: Non-invasive assessment of endothelial function using brachial artery ultrasound is reproducible and can be performed with low intra and inter-observer variability.

Palavras-chave : Inter-observer variability; Endothelial function; Flow-mediated dilation.

        · resumo em Espanhol     · texto em Inglês     · Inglês ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons