vol.85 número3Síndrome cardiorrenal tipo 1 en la unidad de cuidados intensivos coronarios del Hospital Nacional Arzobispo LoayzaFactores de riesgo de mortalidad intrahospitalaria en pacientes con endocarditis infecciosa y accidentes cerebrovasculares: Estudio correlativo de hallazgos clínicos, ecocardiográficos, microbiológicos y neuroimágen índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Archivos de cardiología de México

versão On-line ISSN 1665-1731versão impressa ISSN 1405-9940

Resumo

PARRA-BRAVO, José Rafael et al. Lung perfusion studies after percutaneous closure of patent ductus arteriosus using the Amplatzer Duct Occluder in children. Arch. Cardiol. Méx. [online]. 2015, vol.85, n.3, pp.188-194. ISSN 1665-1731.  https://doi.org/10.1016/j.acmx.2014.12.003.

Objective: The closure of patent ductus arteriosus with multiple devices has been associated with a reduction in lung perfusion. We evaluated the pulmonary perfusion after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder device using perfusion lung scan. Methods: Thirty patients underwent successful percutaneous patent ductus arteriosus occlusions using the Amplatzer Duct Occluder device were included in this study. Lung perfusion scans were preformed 6 months after the procedure. Peak flow velocities and protrusion of the device were analyzed by Doppler echocardiography. A left lung perfusion < 40% was considered abnormal. Results: The device implantation was successful in all patients. Average perfusion of left lung was 44.7 ± 4.9% (37.8-61.4). Five patients (16.6%) showed decreased perfusion of the left lung. Age, low weight, the length of the ductus arteriosus and the minimum and maximum diameter/length of the ductus arteriosus ratio were statistically significant in patients with abnormalities of lung perfusion. It was observed protrusion the device in 6 patients with a higher maximum flow rate in the left pulmonary artery. Conclusion: The left lung perfusion may be compromised after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder. The increased flow velocity in the origin of the left pulmonary artery can be a poor indicator of reduction in pulmonary perfusion and can occur in the absence of protrusion of the device.

Palavras-chave : Patent ductus arteriosus; Percutaneous closure; Amplatzer Duct Occluder; Lung perfusion scan; México.