SciELO - Scientific Electronic Library Online

 
vol.88 número5Efecto agudo del consumo de yerba mate (Ilex paraguariensis) sobre el ritmo cardíaco en pacientes derivados para estudio HolterCélulas madre: buscando marcadores de superficie celular que predispongan compromiso de diferenciación cardiaca índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Archivos de cardiología de México

versão On-line ISSN 1665-1731versão impressa ISSN 1405-9940

Resumo

CHAVEZ-GONZALEZ, Elibet; BARJA, Luis D.; ORTEGA, Daniel F.  e  PEREZ-RODRIGUEZ, Alexis. Permanent septal pacing in patients suffering secondary heart failure compared to right ventricular apical pacing. Arch. Cardiol. Méx. [online]. 2018, vol.88, n.5, pp.474-482.  Epub 04-Dez-2020. ISSN 1665-1731.  https://doi.org/10.1016/j.acmx.2018.05.008.

Introduction:

Regardless of the type of electrical stimulation (VVI or DDD) the highest percentage of right ventricular apical pacing can cause left ventricular failure. For this reason, studies have been performed in different sites on right ventricle pacing.

Objective:

To describe differences between electrocardiography and echocardiography variables during right ventricular apical pacing and septal pacing.

Methods:

A total of 24 patients were studied, 2 women and 22 men, with heart failure due to conventional pacing on right ventricular (ejection fraction ≤ 35%). An electrocardiogram as well as an echocardiogram, was performed during right ventricular apical pacing and when patients were paced on septal area.

Results:

The ejection fraction increased from 31 ± 3.1% to 45 ± 12% (P=.0041) on septal pacing, showing higher degree of mechanic synchronisation.

Conclusions:

Pacing on septal area could be a good site for those patients that suffer heart failure due to right ventricular apical pacing. These must show narrow QRS on their intrinsic electrocardiographic conduction. This kind of pacing can produce an improvement in electro- mechanical synchronisation, as well as show an increased left ventricular ejection fraction.

Palavras-chave : Pacemaker; Heart failure; Electromechanical synchronisation; Septal pacing; Cuba.

        · resumo em Espanhol     · texto em Espanhol