vol.94 número1Prevalencia de estenosis aórtica moderada-grave en pacientes con amiloidosis cardiaca en un centro de referenciaEvaluación de signos vitales mediante una aplicación móvil en pacientes con insuficiencia cardiaca: ¿una oportunidad para la titulación remota? índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Archivos de cardiología de México

versão On-line ISSN 1665-1731versão impressa ISSN 1405-9940

Resumo

GOMEZ-ALVAREZ, Ulises et al. Experience with the Kosmos ultrasonographic tool in the approach and treatment of ambulatory patients of a heart failure clinic: a single-center cross-sectional study. Arch. Cardiol. Méx. [online]. 2024, vol.94, n.1, pp.79-85.  Epub 07-Maio-2024. ISSN 1665-1731.  https://doi.org/10.24875/acm.22000250.

Background:

In Mexico, the epidemiology of heart failure is still not well understood. However, it is known that the primary cause of hospital admissions in patients with heart failure is pulmonary and systemic congestion.

Objective:

To estimate congestion status and assess cardiac function using portable ultrasound in patients with heart failure.

Method:

A cross-sectional observational study was conducted. Patients who attended the Heart Failure Clinic at the Ignacio Chávez National Cardiology Institute in Mexico City between May and August 2022 were selected. They underwent ultrasonographic evaluation using a portable device to assess pulmonary and systemic congestion, as well as cardiac function and structure.

Results:

One-hundred patients diagnosed with heart failure were prospectively included during the study period; 76% were male, with an average age of 59 years (range: 50-68 years). The recorded LVEF median was 34% (IQR: 27-43.5%). When evaluating pulmonary congestion, 78% of the patients showed a pattern A and 22% a pattern B. Following the VExUS protocol, 92% of the patients were at grade 0, 2% at grade 1, and 6% at grade 2.

Conclusions:

The use of the portable ultrasound facilitated the quantitative characterization of the echocardiographic features of the studied population. This device could provide better clinical characterization which, in turn, might allow for optimized drug prescription for heart failure and dose adjustments of diuretics based on echocardiographic congestion findings.

Palavras-chave : Systemic and pulmonary congestion; Heart failure; Echocardiogram.