SciELO - Scientific Electronic Library Online

 
vol.49 número3Effect of Support Acidity on n-heptane Reforming over Pt/Beta zeolite+γAlumina Catalysts índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Journal of the Mexican Chemical Society

versão impressa ISSN 1870-249X

Resumo

ROBLES MARTINEZ, Héctor Alfredo; CUEVAS RODRIGUEZ, Germán  e  HERNANDEZ CASTILLO, Daniel. Determination of PCBs in Transformers Oil Using Gas Chromatography with Mass Spectroscopy and Aroclors (A1254:A1260). J. Mex. Chem. Soc [online]. 2005, vol.49, n.3, pp.263-270. ISSN 1870-249X.

The current study shows a calibration method in gas chromatography (GC) with detection by mass spectrometry (MS) to quantify polychlorinated biphenyls (PCBs) present in transformer oils. The calibration was carried out with a secondary standard composed of a mixture of Aroclors (A1254:A1260), in one to one proportion and a reference standard (1,3,5-trichlorobenzene). This last one was used to evaluate the answer of the MS. The limit of detection of the method was below 10 µg/mL, with ± 0.002 as deviation in the relative retention time (RRT) and 3.39 % as relative response factor (RRF). Finally, PCBs concentration in oil samples was determined from the calibration data.

Palavras-chave : Polychlorinated Biphenyls; Transformer oils; Aroclor; Mass Spectrometry.

        · resumo em Espanhol     · texto em Inglês     · Inglês ( pdf )

 