Passive neutron area monitor with TLD pairs
K.A. Guzmán-García, C.G. Borja-Hernández, C. Valero-Luna, V.M. Hernández-Dávila, and H.R. Vega-Carrillo
Unidad Académica de Estudios Nucleares Universidad Autónoma de Zacatecas, C. Ciprés 10, Fracc. La Peñuela, 98068 Zacatecas, Zac. fermineutron@yahoo.com
Recibido el 3 de junio de 2011;
aceptado el 8 de febrero de 2012
Abstract
The response of a passive neutron area monitor with pairs of thermoluminescent dosimeters has been calculated using the Monte Carlo code MCNP5. The response was calculated for one TLD 600 located at the center of a polyethylene moderator. The response was calculated for 47 monoenergetic neutron sources ranging from 1E(-9) to 20 MeV. Response was calculated using two irradiation geometries, one with an upper source and another with a lateral source. For both irradiation schemes the response was calculated with the TLD in two positions, one parallel to the source and another perpendicular to the source. The advantage of this passive neutron monitor area is that can be used in locations with intense, pulsed and mixed radiation fields like those in radiotherapy vault rooms with linear accelerators.
Keywords: Neutron; ambient dose equivalent; area monitor.
Resumen
La respuesta de un monitor de área pasivo para neutrones con pares de dosímetros termoluminiscentes TLDs ha sido calculada mediante métodos Montecarlo con el código MCNP5. La respuesta fue calculada para un TLD 600 localizado en el centro del moderador cilíndrico de polietileno. La respuesta se calculó para 47 fuentes mono energéticas de neutrones con energías de 1E (-9) a 20 MeV. La respuesta se calculó para dos geometrías de irradiación, una con una fuente superior y la otra con una fuente lateral, para ambas geometrías la respuesta se obtuvo con el TLD en dos posiciones respecto a la fuente, una perpendicular y la otra paralela. La ventaja del monitor pasivo es que puede ser usado en instalaciones con campos de radiación intensos, pulsados y mixtos como los que se producen en los bunkers de radioterapia con aceleradores lineales.
Descriptores: Neutrón, dosis equivalente ambiental, monitor de área.
14.20.Dh; 87.58.Sp; 29.90.+r
DESCARGAR ARTÍCULO EN FORMATO PDF
References
1. T.J. Dunai, Cosmogenic Nuclides: Principles, concepts and applications in the Earth surface sciences. (Cambridge University Press, Cambridge UK. 2010). pp. 3-6. [ Links ]
2. S. Pszona, Neutrons in natural environment. (Proccedings of IRPA Regional Symposium, 1997) pp. 157-160. [ Links ]
3. J.W. Leake, Nucl. Instrum. Meth., 45 (1966) 151. [ Links ]
4. H.R. Vega-Carrillo, E. Manzanares, Nucl. Instrum. Meth. Phys. Res. A, 524 (2004) 146. [ Links ]
5. H.R. Vega-Carrillo, Nucl. Instrum. Meth. Phys. Res. A, 463 (2001) 375. [ Links ]
6. J.M. Gómez-Ros, R. Bedogni, M. Moraleda, A. Romero, A. Delgado, A. Esposito, Radiat. Meas. 45 (2010) 1220. [ Links ]
7. H.R. Vega-Carrillo, Radiat. Meas. 35 (2002) 251. [ Links ]
8. S.P. Tripathy, A.K. Bakshi, V. Sathian, S.M. Tripathi, H.R. Vega-Carrillo, M. Nandy, P.K. Sarkar, D.N. Sharma, Nucl. Instrum. Meth. Phys., Res. A, 598 (2009) 556. [ Links ]
9. R. Bedogni, A. Esposito, A. Gentile, M. Angelone, G. Gualdrini, G. Radiat. Meas., 43 (2008) 1104. [ Links ]
10. A. Zanini, E. Durisi, F. Fasolo, L. Visca, C. Ongaro, U. Nastasi, K.W. Burn, J.R.M. Annand, Radiat. Prot. Dosim. 110 (2004) 157. [ Links ]
11. M. Kralik, K. Turek, V. Vondracek, Radiat. Prot. Dosim. 132 (2008) 13. [ Links ]
12. H.R. Vega-Carrillo, V.M. Hernández-Dávila, E. Manzanares- Acuña, E. Gallego, A. Lorente, M.P. Iñiguez, Radiat. Prot. Dosim. 126 (2007) 408. [ Links ]
13. NNDC. [online]. Evaluated Nuclear Data File (ENDF) Retrival & Plotting. http://www.nndc.bnl.gov/sigma/ index.jsp?as=10&lib=endfb7.0&nsub=10 National Nuclear Data Center, Brookhaven National Laboratory. [Reviewed on Nov. 2010]. [ Links ]
14. X-5 Monte Carlo Team, MCNP - A General Monte Carlo NParticle Transport Code, Version 5. Los Alamos National Laboratory Report LA-UR-03-1987 (2003) [ Links ]
15. ICRP 74, Annals of the ICRP 26 (1996) 199. [ Links ]
16. Berthold. [online]. LB 6411-Pb Neutron Dose Rate Probe for High Energy Neutrons. http//www.berthold.com/ww/en/pub/strahlenschutz/produkte/rppldose/lb_6411_6411_pb.cfm. (2008). Berthold Technologies GMBH & Co. [Reviewed on Dec 2010]. [ Links ]
17. J.W. Leake, T. Lowe, R.S. Mason, G. White, Nucl Instrum Meth. Phys. Res. A, 613 (2010) 112. [ Links ]