SciELO - Scientific Electronic Library Online

 
vol.64 número1Molecular Modelling, Docking and Pharmacokinetic Studies of N-Arylidenequinoline-3-Carbohydrazides Analogs as Novel β-Glucuronidase InhibitorsSynthesis of Coumarins Linked With 1,2,3-Triazoles under Microwave Irradiation and Evaluation of their Antimicrobial and Antioxidant Activity índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • No hay artículos similaresSimilares en SciELO

Compartir


Journal of the Mexican Chemical Society

versión impresa ISSN 1870-249X

J. Mex. Chem. Soc vol.64 no.1 Ciudad de México ene./mar. 2020  Epub 31-Dic-2020

https://doi.org/10.29356/jmcs.v64i1.1031 

Articles

Noninvasive Determination of the Amount of Ethanol in Liquid Mixtures by Ultrasound Using Bilinear Interpolation Method

Ahmet Aydın1  * 

Cemil Keskinoğlu1 

Umut Kökbaş2 

Abdullah Tuli3 

1 Department of Biomedical Engineering, Cukurova University, Adana, Turkey.

2 Department of Medical Biochemistry, University of Kyrenia, Girne, Cyprus.

3 Department of Medical Biochemistry, Cukurova University, Adana, Turkey.


Abstract:

Ultrasound is used in many analysis studies, including liquid mixtures. Many mixtures are analyzed to understand their contents or properties in different situations. One of these mixtures is the ethanol-water combination. In this study, the amount of ethanol in the liquid mixture was determined noninvasively by the ultrasonic method using a microcontroller-based system. The results show that the measurements obtained were within the p<0.05 confidence interval. The characteristics evaluation of the system shows that the system can detect ethanol concentration as low as 0.552 g/L, thus the system has a broad and linear determination range for ethanol. Although the system is calibrated and tested with ethanol-water mixture, it can be used for any mixture that changes density related to the substance concentration, including different alcohols which are soluble in water (glycols, glycoethers, etc.) or any other material (solid or liquid) which is soluble in alcohol or different liquid solvent. The system has so many advantages that make it possible to use comfortably in many areas where the amount of ethanol contained in the mixture is essential. These advantages are the high accuracy and sensitivity, being noninvasive, portable, and not having a destructive effect on the substance.

Keywords: TOF measurement; bilinear interpolation; noninvasive ultrasonic method; mixture analysis, alcohol concentration

Resumen:

El ultrasonido es utilizado en muchos estudios incluyendo las mezclas liquidas. Se analizan varias mezclas para entender sus contenidos y propiedades en diferentes situaciones. Una de estas mezclas es la combinación de etanol-agua. En este estudio, la cantidad de etanol en la mezcla líquida fue determinada de manera no invasiva con el método ultrasonico utilizando un sistema basado en microcontrolador. Los resultados muestran que las mediciones obtenidas se encontraban dentro de un intervalo de confianza de p<0.05. Las características de evaluación del sistema muestran que se puede detectar etanol a una concentración tan baja como 0.552 g/L, por lo tanto, el sistema tiene un rango de determinación linear amplio para etanol. Aunque el sistema se calibra y prueba con mezcla de etanol-agua, puede ser utilizado para cualquier mezcla que cambia de densidad en relación con la concentración de la substancia, incluyendo diferentes alcoholes que son solubles en agua (glicoles, glicoeteres, etc) o cualquier otro material (sólido o líquido) que sea soluble en alcohol o en algún solvente líquido diferente. El sistema tiene muchas ventajas que hacen posible su utilización en muchas áreas donde la cantidad de etanol contenida en la mezcla es esencial. Estas ventajas son de alta precisión y sensiblididad al ser no invasivo, portátil y al no tener un efecto destructivo sobre la sustancia.

Palabras clave: Medición del TOF; interpolación bilinear; método ultrasónico no invasivo; análisis de mezclas; concentración de alcohol

Introduction

Ultrasound technologies have become increasingly widespread in many areas. One of these is using ultrasonic velocity measurements to analyze the contents of the mixture [1-7]. The determination of the changes in the number of substances and the amount of each substance contained in the solution is of great importance to monitor the processes, analyze the solution, and determine the contents of foods or mixtures. Measurement of sound velocity and density in the mixtures is also essential in understanding molecular interactions [8].

Ethanol is a water-soluble organic molecule. This feature of ethanol allows it to be used intensively many processes in the industry such as pharmaceutical, food, beverage, cosmetics, paint, medical, and automotive. Ethanol also being used in medicines and also have clinical importance. Its analysis is also essential in the diagnosis and treatment of some disorders (alcohol toxicity, brain trauma, uremia, diabetes acidosis, behavior) [9,10]. Also, it is very important to determine the amount of ethanol in the mixture precisely because the liquid-ethanol mixture is used in the calibration of ultrasonic systems and in some cases the results of the theoretical approach in determining the substance contents do not correspond with the results obtained in the practical study.

Liquid alcohol-water mixtures show unusual properties when the amount of water is high in the mixture. These are usually explained by the molecular relationship leading to cluster formation. Only in some cases; the concentration dependencies of molar heat capacity, partial molar volumes, mixture heat, and sound velocity show substantial deviations from the behavior of ideal systems. While the speed of sound in pure water and pure ethanol is dependent on temperature, in mixtures, the speed is also dependent on the composition of the mixture [11,12].

The determination of the amount of alcohol in biological liquids was carried out for the first time in 20th century, and then it was modified by many researchers [13]. Nowadays, in addition to enzymatic-spectrophotometric based methods for the determination of alcohol, chromatographic, physical-biological-chemical sensor systems are also used extensively [14-16]. Sensor-based methods have a significant advantage over other methods and more preferred for their specificity, quick response, and no need for expensive equipment [17].

In the literature, previous studies were performed using ultrasonic methods in the measurements of ethanol-water mixtures. Meister measured the sound velocity of pure water, pure ethanol and their mixtures with an ultrasonic echometer operating at 4 MHz [12]. Martin and Spinks studied several ethanol/water mixtures and measured the speed of sound in liquid with an accuracy of % 0.1 by controlling the temperature with 1°C precision [18]. Tong et al. measured speed of sound and density of mixture across the range 10 to 50°C with an ultrasound resonator and a densitometer [19].

There are different analysis methods such as hydrometers or digital density meter and expensive analyzers such as gas chromatography for the determination of ethanol [20-22]. All these methods, except ultrasonic technique, are invasive analysis methods. The other studies used ultrasound for analysis use large and expensive lab equipment for the measurement [23-25].

In this study, the ethanol mixture is analyzed noninvasively with only one portable integrated ultrasonic system without the need for any other device such as oscilloscope, signal generator etc. The noninvasive analysis is important since it can be applied quickly and does not have any destructive effect on the sample. Having an integrated system for the measurement gives an advantage in terms of cost, portability, and ease of use. In this study, a practical approach has been developed to determine alcohol concentration rapidly with high accuracy in liquid mixtures. Since the density of the alcohol in the environment is highly correlated with the ambient temperature, problems may arise in the accuracy of the measurements if the system is not calibrated regarding the temperature. For a more reliable measurement, several liquid mixtures were prepared and analyzed with distilled water and ethanol. For the analysis, ultrasound signal was generated by a microcontroller, and then this ultrasonic signal was applied to the liquid mixture in a container using a piezoelectric transducer. Since the distance of the container where the ultrasonic signal is propagated is constant, the sound speed can be calculated from the measured time of flight (TOF) of the ultrasound wave. In this study, the TOF values are measured, and the change in these values was analyzed to find the amount of ethanol in the mixture utilizing the interpolation method.

Theory

The sound is a mechanical wave. Therefore, it needs a medium to propagate. As the sound wave is influenced by the changes in the propagation environment, a change in the TOF is evaluated and used to analyze the properties of the environment, such as temperature, density, and pressure.

The formula used for the speed of sound at compressible fluids, including liquids is given in Eq. 1.

c= βρ 1

In this formula, c is the sound speed, β is the Bulk module, i.e., the inverse of compressibility, and ρ is the density of the medium. As seen from the formula, a change in the density causes a change in sound velocity [26]. Depending on the change at speed, the measured TOF will change as well.

The time elapsed between the generation of the sound wave by the transmitter piezo disc and its detection by receiver piezo disc is called time of flight (TOF). In this study, a single piezoelectric ceramic disc transducer is used for both the production and detection of the sound wave. This principle is called the pulse-echo principle and it is the event that the ultrasonic wave produced by the piezoceramic is reflected back from a certain surface, and the same piezoelectric transducer detects this reflected sound wave. According to this principle, the TOF value is calculated according to Eq. 2.

TOF= 2.dc 2

where 𝑑, 𝑐, and 𝑇𝑂𝐹 represent the width of the container, the propagation speed of the sound wave in the medium, and time of flight, respectively. Since single piezo is used for both creating and sensing of the sound wave, the total distance will be 2𝑑. When measuring TOF, firstly a start wave is generated to create the ultrasonic wave, and then a stop wave is created when the echo above a certain threshold level is detected. The time between the start wave and stop wave gives the TOF. The system can measure TOF in nanosecond precision. The oscilloscope image of start wave, stop wave, and echo together with stop wave is shown in Fig.1.

Fig. 1 The oscilloscope images of start, stop, and echo waves. 

Since the density of the liquid mixture and consequently the TOF value depends on temperature and ethanol concentration, the bilinear interpolation method was used to determine the amount of ethanol for unmeasured intermediate temperatures and concentrations.

For bilinear interpolation, linear interpolation is applied on both 𝑥 and 𝑦−axes which represents temperature and TOF values (Fig. 2). The A11,A12,A21,A22 in Fig.2 represent the TOF values measured during calibration of the system at a known concentration and temperature values, and 𝑇 is the value should be determined at an intermediate temperature and concentration which is not measured previously.

Fig. 2 Bilinear interpolation graph. 

The steps or the bilinear interpolation are as follows: firstly, linear interpolation is applied on the 𝑥−axis with Eq.3 and Eq.4 to find the values of 𝐵 1 and 𝐵 2 on Fig. 2,

fx,y1=fB1= x2-xx2-x1 fA11+ x-x1x2-x1 fA21 3

fx,y2=fB2= x2-xx2-x1 fA12+ x-x1x2-x1 fA22 4

and then on the 𝑦−axis with Eq.5 to find the value of 𝑇 on Fig. 2 which represents TOF value for an unmeasured temperature and concentration.

fx,y=fT= y2-yy2-y1 fB1+ y-y1y2-y1 fB2 5

When the Eq. 5 is examined, it is seen that this equation is related to f(B1) and f(B2) in Eq. 3 and 4. When these two functions, are substituted in Eq.5, 𝑓 𝑥,y given in Eq. 6 is obtained [27].

fx,y=fT= y2-yy2-y1x2-xx2-x1 fA11+x-x1x2-x1 fA21+y-y1y2-y1x2-xx2-x1 fA12+x-x1x2-x1 fA22 6

By solving Eq.6, final definition of bilinear interpolation is obtained as given in Eq. 8

fx,y= 1x2-x1y2-y1 fA11x2-xy2-y+fA21x-x1y2-y+fA12x2-xy-y1+fA22x-x1y-y1 7

fx,y=fT= 1x2-x1y2-y1x2-xx-x1fA11fA12fA21fA22y2-yy-y1 8

The student t-test was used to check the relevance of the results by testing if there is a statistically significant difference between the variables, or the observed average value is different from the default values. This test is also known as a small sample testing technique since can be applied when 𝑛 <30 or in cases where the mean of the average mass is suspected to be normal [28]. The formula of the test is given at Eq. 9., where 𝜇, 𝑠 are the mean and variance of the sample respectively, and 𝑛 is number of samples [29].

t= μ1-μ2sp21n1+1n2 9

Experimental

In this study, the amount of ethanol in the liquid mixture was determined by measuring TOF [30]. The measurement data is obtained by firstly putting 200 ml pure water into a container and then adding 70° ethanol with 0.2 ml steps until 5 ml. For each ethanol concentration, the temperature has been changed from 296 K to 308 K with one-kelvin steps. And the measurements are done for all concentration and temperature combinations. Therefore 338 measurement data points are obtained from 26 different concentrations at 13 different temperatures. For the temperature control, a water bath with +/- 0.1 °C temperature stability is used. The dimensions of the container are 72x95 mm, and wall thickness is 1 mm. For the transducer, a 1 MHz piezoelectric ceramic disc with 20 mm diameter and shielded cable is used.

The transducer is glued to the acrylic container from the outer corner with a special cyanoacrylate adhesive to ensure the high propagation of the ultrasound wave. Before gluing the transducer, the surface is sanded to increase the adhesion. For the measurements TI TDC1000 - TDC7200EVM is used and system controlled with the onboard TI MSP430F5528 microcontroller [31]. For the data acquisition, a LabVIEW GUI and for the analysis MATLAB is used. The block diagram of the system is given in Fig. 3.

Fig. 3 Block diagram of the system. 

TI TDC1000 - TDC7200EVM is a module that can generate and receives ultrasonic waves then find the TOF in nanoseconds. The module has a GUI for parameter settings and data acquisition. It can be configured to work in 3 different modes: Mode 0 for level and fluid identification using 1 piezo transducer, Mode 1 for single one direction TOF measurement and, Mode 2 for water flow metering applications [32]. The module has two measurement channels and each channel can be configured to use one or two different piezo for TOF measurements, Fig 4.

Fig. 4 TDC1000-TDC7200 EVM pinout. TX1, RX1 and TX2, RX2 are transmitter and receiver transducers of channels one and two, respectively. AVDD is system power pin and finally RTD1, RTD2 are temperature sensor pins. 

Since one piezo is used at channel two for TOF measurement, TOF_MEAS_MODE register is configured as Mode 0, MEAS_MODE register as TOF measurement, and the CH_SEL register as CH2, Fig. 5.

Fig. 5 TDC1000-TDC7200EVM GUI Parameter Setting. 

Results and discussion

All the TOF measurements used in the study are given in the Appendix as Tables 1. The TOF graph at different temperatures of different concentrations after interpolation is given in Fig 6. Each plot in the graph represents the amount of ethanol in 0.2 ml increments from 0 ml to 5 ml. From the graph in Fig. 6, it is clearly seen that the TOF values change due to the increase in the amount of ethanol in the mixture and temperature.

Table 1 Measured TOF values (296 - 308 K). 

Ethanol(ml) Kelvin(K)
296 297 298 299 300 301 302 303 304 305 306 307 308
0 97556 97523 97432 97437 97406 97337 97357 97317 97225 97269 97294 97200 97215
0.2 97493 97478 97407 97404 97355 97277 97290 97242 97158 97179 97188 97105 97101
0.4 97479 97455 97384 97373 97319 97234 97242 97191 97111 97120 97124 97037 97031
0.6 97461 97430 97358 97347 97283 97199 97201 97146 97070 97072 97070 96969 96957
0.8 97443 97403 97333 97319 97249 97159 97160 97100 97030 97017 97006 96913 96897
1 97424 97378 97305 97289 97212 97123 97121 97060 96990 96967 96954 96854 96843
1.2 97403 97353 97280 97258 97179 97085 97081 97011 96949 96919 96904 96802 96788
1.4 97383 97329 97253 97230 97146 97053 97043 96976 96902 96875 96857 96745 96736
1.6 97366 97303 97227 97202 97110 97020 97003 96935 96865 96825 96811 96697 96684
1.8 97341 97276 97201 97169 97077 96992 96968 96892 96831 96786 96757 96653 96635
2 97320 97252 97174 97140 97043 96959 96930 96850 96795 96743 96719 96608 96591
2.2 97297 97228 97149 97109 97012 96928 96898 96811 96763 96700 96674 96564 96544
2.4 97273 97200 97124 97080 96977 96896 96860 96780 96725 96666 96636 96523 96501
2.6 97247 97176 97101 97054 96946 96864 96826 96742 96693 96623 96592 96478 96460
2.8 97221 97149 97077 97026 96916 96832 96791 96703 96659 96586 96549 96438 96418
3 97196 97123 97051 96996 96883 96806 96758 96669 96624 96549 96509 96396 96375
3.2 97169 97097 97025 96966 96852 96774 96726 96627 96590 96512 96470 96356 96335
3.4 97146 97067 96997 96934 96823 96741 96696 96598 96554 96479 96436 96313 96297
3.6 97119 97038 96969 96906 96792 96713 96667 96565 96523 96443 96399 96279 96260
3.8 97091 97012 96941 96879 96764 96684 96638 96531 96487 96411 96364 96241 96217
4 97064 96995 96914 96849 96736 96654 96604 96499 96453 96379 96331 96209 96185
4.2 97038 96954 96890 96821 96709 96624 96574 96468 96425 96343 96299 96179 96154
4.4 97012 96928 96862 96794 96680 96598 96545 96435 96393 96311 96265 96139 96121
4.6 96984 96900 96835 96766 96651 96568 96518 96406 96362 96283 96233 96110 96086
4.8 96955 96869 96810 96741 96620 96537 96487 96375 96331 96248 96201 96082 96053
5 96929 96842 96784 96713 96591 96509 96459 96344 96301 96216 96167 96047 96020

Fig. 6 Temperature - TOF Graph in the ethanol-water mixture. The TOF values were measured in nanoseconds, while the temperature values in Kelvin. The top plot shows the case when there is 0 ml while the bottom plot when there is 5 ml ethanol in the mixture and the other plots in between are for the TOF values in each 0.2 ml ethanol increase in the mixture, respectively. 

The top plot in the graph of Fig. 6 shows the case when there is 0 ml while the bottom plot when there is 5 ml ethanol in the mixture and the other plots in between are for the TOF values in each 0.2 ml ethanol increase in the mixture, respectively. When the graph is analyzed, it is clear that there is a decrease in TOF values due to the change in the speed of sound while the amount of ethanol in the mixture does not change and the temperature is increasing. Likewise, the increase in the amount of ethanol in the mixture when the temperature is constant, the speed of sound has changed and the TOF values have decreased since the density of the liquid changes. Since the distance is constant, the speed of sound is calculated from TOF values at different temperatures and a curve is fitted for a smooth representation, Fig. 7[25]. The top plot in the graph of Fig. 7 shows the case when there is 5 ml while the bottom plot when there is 0 ml ethanol in the mixture and the other plots in between are for the TOF values in each 0.2 ml ethanol increase in the mixture, respectively.

Fig. 7 Temperature - Speed of sound Graph in ethanol-water mixture. The speed in meter/seconds and temperatures in Kelvin. The top plot shows the case when there is 5 ml while the bottom plot when there is 0 ml ethanol in the mixture and the other plots in between are for the TOF values in each 0.2 ml ethanol increase in the mixture, respectively 

As expected, the density of the mixture changed when the amount of ethanol is increased, and this resulted in an increase in the speed of sound discernibly between each case. Also it can be seen that a slight change in the ethanol concentration or the temperature, outcomes in a measurable change in the TOF.

For the performance evaluation of the system, half of the data is used for bilinear interpolation (0.2 - 0.6 - 1 - 1.4 - 1.8 - 2.2 - 2.6 - 3 - 3.4 - 3.8 - 4.2 - 4.6 - 5.0 ml) and the other half for testing (0.4 - 0.8 - 1.2 - 1.6 - 2 - 2.4 - 2.8 - 3.2 - 3.6 - 4 - 4.4 - 4.8 ml). The bilinear interpolation is applied with 0.01 steps for both added ethanol and temperature. Therefore, a lookup table for temperatures between 296 - 308 K and ethanol amount between 0.2 - 5 ml with 0.01 steps is obtained. Therefore, on the contrary to the other studies, after measurement of the temperature and TOF values, the amount of ethanol contained in the mixture can be directly found from the lookup table (Fig.8) with high accuracy and precision without further mathematical calculations [18].

Fig.8. Block diagram of finding the amount of ethanol from lookup table. 

For the performance evaluation, the percentage relative error (PRE) and mean absolute percentage error (MAPE) is calculated using Eq. 10 and 11, respectively. The min, mean, and max absolute percentage error of the results are given at error bar graph in Fig. 9. From the results, it can be seen that the accuracy and as well as the precision of the system is high.

PRE= Actual Values-Predicted ValuesActual Values x 100 10

MAPE= 1nPREin   11 11

Fig. 9 Temperature - range of the mean absolute percentage error graph. 

When the MAPE values in all measurements are examined, it is seen that these error values are very low. This is important because it shows that very low ethanol concentration changes can be detected with high accuracy in performed study. Thus, the study can be expanded in areas where ethanol content analysis is important such as food engineering, biomedical engineering, biochemistry etc. In addition to the mixture analysis studies, it can be performed in different studies such as process monitoring studies both industrial and biological fields or analysis of biological samples such as blood, urine, etc. Another advantage is that, on the contrary to the other studies, all the measurements can be performed and analyzed without a signal generator and an oscilloscope [25].

Conclusion

The ethanol is widely used in many industrial areas such as pharmaceutical, food, beverage, cosmetics, paint, medical, and automotive. Therefore, it is essential to analyze its concentration at the mixtures with high precision. The ultrasonic measurement method is an important and preferred method due to its accuracy, being cheap and noninvasive, and not having destructive effects on the material to be measured. In the study, the bilinear interpolation method is used to find the amount of ethanol contained in the mixture with high accuracy at different temperature values.

The currently available alcohol concentration measurement systems are invasive and/or use too many lab equipments that increase the total system cost and make them difficult to relocate and to use. Therefore, the main contributions of the study are high accuracy and precision with only a single board which makes it highly portable, and cost much less when compared with the currently available measurement systems.

Although the system is calibrated and tested with ethanol-water mixture, it can be used for any mixture that changes density related to the substance concentration, including different alcohols which are soluble in water (glycols, glycol ethers, etc.) or any other material (solid or liquid) which is soluble in alcohol or different liquid solvent.

The characteristics of the system indicate that the system has a broad and linear determination range for the ethanol starting from 0.552 g/L and the detectability of the system is statistically within the p <0.05 confidence interval. The standard deviation of the measurements is 0.21. Therefore, the system with the advantages of not requiring extra equipment and mathematical calculations to find even very low concentrations of ingredients in the sample with high accuracy.

References

1. Chen, F., Yang, Z, Chen, Z. , Hu,J., Chen, C. and Cai J. J. of Mol. Liq. 2015, 209, 683-692. [ Links ]

2. Gowrisankar, M., Venkateswarlu, P., Sivakumar, K. and Sivarambabu, S. Arabian J. of Chem. 2017, 10, S2625-S2636. [ Links ]

3. Hevia, F., Cobos, A., González, J.A., de la Fuente, I.G. and Alonso V. J. of Solution Chem. 2017, 46, 150-174. [ Links ]

4. Salinas, R., Pla-Franco J., Lladosa, E. , and Montón, J.B. J. of Chemical & Engineering Data, 2015, 60, 525-540. [ Links ]

5. Shekaari, H., Zafarani-Moattar, M.T., and Faraji, S. J. of Chemical & Engineering Data, 2017, 62, 4187-4195. [ Links ]

6. Varfolomeev, M.A., Rakipov, I.T., Solomonov, B.N., and Marczak, W. J. of Chemical & Engineering Data, 2016, 61, 1032-1046. [ Links ]

7. Zarei, H. and Keley, V. J. of Chemical & Engineering Data, 2017, 62, 913-923. [ Links ]

8. Rowlinson, J.S. and Swinton, F. Liquids and liquid mixtures: Butterworths monographs in chemistry. 2013, Butterworth-Heinemann. [ Links ]

9. Park, R. West J. of Med., 1980, 133, 418. [ Links ]

10. Lieber, C.S. Alcohol.: Clin. and Exp. Res. 1991, 15, 573-592. [ Links ]

11. Giacomini, A. J. Acoust. Soc. of Am. 1947, 19, 701-702. [ Links ]

12. Meister, E.C., Measurement of the Temperature and Concentration Dependent Sound Velocity in Ethanol-Water Liquid Mixtures. 2015. [ Links ]

13. Widmark, E.M. Acta Med. Scand. 1919, 52, 87-164. [ Links ]

14. Akyilmaz, E. and Dinçkaya, E. Talanta 2003. 61, 113-118. [ Links ]

15. Heberle, I., Liebminger, A., Weimar, U., and Göpel, W. Sens. Actuators, B 2000, 68, 53-57. [ Links ]

16. Rahman, M.M., Jamal, A., Khan, S.B., and Faisal, M. Biosens. Bioelectron. 2011, 28, 127-134. [ Links ]

17. Azevedo, A.M., Prazeres, D.M.F., J.M. Cabral, and Fonseca, L.P. Biosens. Bioelectron. 2005, 21, 235-247. [ Links ]

18. Martin, K. and Spinks, D. Ultrasound in medicine & biology, 2001, 27, 289-291. [ Links ]

19. Tong, J., Povey, M. Zou, X. Ward, B. and Oates, C. J. of Phys.: Conf. Ser. 2011, IOP Publishing. [ Links ]

20. Curry, A., Walker, G. and Simpson, G. Analyst, 1966, 91, 742-743. [ Links ]

21. Gonzalez-Rodrıguez, J., Pérez-Juan, P. and M.L. De Castro, M.L. Talanta 2003, 59, 691-696. [ Links ]

22. Qi, X., Zhang, Y., Tu, R., Lin, Y., Li, X. and Q. J. Appl. Microbiol. 2011, 110, 1584-1591. [ Links ]

23. Kazys, R., Rekuviene, R., Sliteris, R., Mazeika, L. and Žukauskas, E. Ultrasonic technique for monitoring of liquid density variations. Vol. 86. 2015, 015003. [ Links ]

24. Geier, D., Heermann, K. Hussein, M. and Becker, T. Eng. Life Sci. 2014, 14,433-441. [ Links ]

25. Vatandas, M., Koc, A.B. and Koc, C. Eur. Food Res. and Technol. 2007, 225, 525-532. [ Links ]

26. Smith, N.B.; Webb, A. Introduction to medical imaging: physics, engineering and clinical applications. Cambridge university press, 2010. [ Links ]

27. Hughes, J.F.; Van Dam, A.; Foley, J.D.; McGuire, M.; Feiner, S.K.; Sklar, D.F; Akeley, K. Computer graphics: principles and practice. Pearson Education, 2014. [ Links ]

28. Scott, A.J. and Knott, M. A cluster analysis method for grouping means in the analysis of variance. Biometrics, 1974, 507-512. [ Links ]

29. Ruxton, G.D. Behav. Chem. Eco. 2006, 17, 688-690. [ Links ]

30. Keskinoğlu, C., Analiz Ve Proses Takip Çalışmaları İçin Ultrasonik Cihaz Tasarımı Ve Üretimi (Ultrasound Device Design And Production For Analysis And Process Monitoring Studies), in Department of Biomedical Engineering. 2019, Cukurova University. [ Links ]

31. TDC1000-TDC7200EVMUser’sGuide, TDC1000-TDC7200EVM User’s Guide , http://www.ti.com/lit/ug/sniu021a/sniu021a.pdf. 2015. [ Links ]

32. TDC1000 Ultrasonic Sensing Analog Front End (AFE) for Level Sensing, F.S., Concentration Sensing, and Proximity Sensing Applications, http://www.ti.com/lit/ds/symlink/tdc1000.pdf. 2015. [ Links ]

Received: August 05, 2018; Accepted: June 21, 2019

*Corresponding author: Ahmet Aydın, email: aaydin@cu.edu.tr

Creative Commons License This is an open-access article distributed under the terms of the Creative Commons Attribution License