Servicios Personalizados
Revista
Articulo
Indicadores
- Citado por SciELO
- Accesos
Links relacionados
- Similares en SciELO
Compartir
Journal of applied research and technology
versión On-line ISSN 2448-6736versión impresa ISSN 1665-6423
J. appl. res. technol vol.1 no.3 Ciudad de México dic. 2003
Low noise low power readout circuit for soft X ray detection
A. Cerdeira-Estrada1, A. De Luca2, A. Cuttin3 & R. Mutihac4
1 Telital Spa, Trieste Italy, alberto.cerdeira@telit.net
2 Depto. de Ingeniería Eléctrica, Sección de Computación, CINVESTAV-IPN, México D. F.,
3 Laboratory of Microprocessors, ICTP-INFN, Trieste Italy.
4 University of Bucharest, Electronic Department, Romania.
Received: September 18th 2000.
Accepted: August 26th 2002.
Abstract
A new low power CMOS ASIC for the detection of X-rays was optimized for low power and low noise. Theoretical calculations and optimizations are presented and compared with experimental results. Noise as low as 120+25-Cin [pF] ENC rms was obtained including a silicon detector of 1.3 pF and 0.3nA of leakage. The power consumption is less than 100 W. Other circuit parameters are also shown.
Keywords: Charge sensitive amplifiers, Equivalent noise charge, Sharper.
DESCARGAR ARTÍCULO EN FORMATO PDF
References
[1] Cerdeira A., Cuttin A., Fratnik F., Mutihac R. & Colavita A., "Readout electronics in large detector matrix for soft X-ray in medical applications'' Nuclear Instruments and Methods in Physics Research, Section A: Vol. 409 (1-3) 1998, pp. 497-500. [ Links ]
[2] Sansen W. & Chang Z.Y., IEEE. Transactions on Circuits and System, Vol. 37 (11) 1990, pp. 13-75. [ Links ]
[3] Chang Z.Y. & Sansen W., Effect of 1/f noise on resolution of CMOS analog readout system for microstrip and pixel detectors, Nuclear Instruments and Methods in Physics Research, Section A: Vol. 305 (8) 1991, pp. 553. [ Links ]
[4] Cicuttin A., Cerdeira A., Fratnik F., Colavita A. & Vacchi A., , "Medusa-32: a low noise, low power silicon strip detector front-end electronics for space applications", Nucl. Instr. and Meth. in Phys. Res. A 390, 1997. [ Links ]
[5] Zhou C.Z. and Warburton K., "Noise Analysis of Low Noise, High Count Rate, PIN Diode X-Ray Detectors". IEEE Trans. On Nuclear Science. 43(3)13-85, 1996. [ Links ]
[6] Arfelli F., Barbiellini G., Bonvicini V., Bravin A., Cantatore G., Castelli E., Cristaudo P., Di Michiel M., Longo R. & Olivo A., "A digital readout system for the SYRMEEP silicon strip detectors" INFN/TC-96/24, Nucl. Instr. and Meth. in Phys. Res. A 392, 1997. [ Links ]